CP12 & 6 Head Part Exchange - Z-Axis Motor en.pdf - 第12页
在线预览 CP12 & 6 Head Part Exchange - Z-Axis Motor en.pdf PDF 文档。

E-by SIPLACE CP12 & CP6 Removal of the Z-Axis motor
Part Exchange
1/1
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: PN: 03083864
1. Remove the plugs (motor tacho and incre-
mental encoder) from the sockets on interme-
diate distributor.
2. Loosen the upper M2.5x12 hexagon sock-
et-head screw of the motor clamp fitting, then
the lower one.
3. Loosen the two M3x14 hexagon socket-
head screws on the motor clamp fitting.
4. Remove the Z-Axis motor together with the
cables.


E-by SIPLACE CP12 & CP6 Assemble Back the Z-Axis Motor
Part Exchange
1/1
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: PN: 03083864
1. Insert the Z-Axis motor. 2. Ensure that the teeth of the tooth belt en-
gage in the teeth of the motor pinion.
3. Use the four M3x5 hexagon socket-head
screws to fit the Z-Axis motor.