CP12 & 6 Head Part Exchange - Z-Axis Motor en.pdf - 第9页
E-by SIPLACE CP12 & CP6 Removing the Head Front Part Part Exchange 1/2 CAUTION! Refer to safety inst ructions in user manual before working on the machine. ESD guidelines are to be followed Tool: Wear Part: Consum ab…


E-by SIPLACE CP12 & CP6 Removing the Head Front Part
Part Exchange
1/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
1. Remove the compressed air hose for the
blast air.
2. Disconnect the connection cable plug off
the gantry board.
3. Unplug the connection cable from sockets
in the base adapter and vision digital.
4. Carefully hold the DLM head and loosen the
four screws fastening the front part of the
head.
5. Put the front part of the C&P head on a
clean, soft and ESD material-proof surface.
6. Remove all the plungers and store properly.

E-by SIPLACE CP12 & CP6 Removing the Head Front Part
Part Exchange
2/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
7. Remove all the sleeves and store properly.