Level accuracy
Relative to CW signal
Test conditions: ALC off, with power alignment performed
Frequency
1
50 MHz to 15 GHz ± 0.75 dB
> 15 GHz to 20 GHz ± 1.0 dB
> 20 GHz to 32 GHz ± 0.75 dB
Video feed through
Frequency Vector mode, spec (typ) Wideband or enhanced vector mode
< 1.8 GHz 250 mV p–p (100)
≥ 1.8 GHz 25 mV p–p (20)
< 1.2 GHz 250 mV p–p (100)
≥ 1.2 GHz 25 mV p–p (20)
Pulse compression
Mode Vector mode
2
Wideband or enhanced vector mode
3
External LO ± 5 ns ± 2.5 ns
Internal LO
4
± 5 ns
1. Measured at the RF center frequency of the pulse.
2. Measurement conditions: pulse rise/fall times are 16 ns each, pulse width = 100 ns, pulse period = 1 us.
3. Measurement conditions: pulse rise/fall times are 5 ns each, pulse width = 20 ns, pulse period = 500 ns.
4. Internal LO specifcation only applies up to 20 GHz.
Page 20
Find us at www.keysight.com
Internal Baseband Generator
Channels
2 digital channels, I and Q. (no analog inputs or outputs)
Resolution
16 bits (1/65,536)
Baseband waveform memory (playback)
Sample rate Standard memory size Option BBM
250 MSa/s 512 MSa per channel 6 GSa per channel
2 GSa/s (opt BB1 or BB2 only) 512 MSa per channel 4 GSa per channel
Waveform memory (non–volatile storage on removable SSD drive)
512 GBytes
Waveform segments
Vector mode Wideband or enhanced vector
mode
Minimum segment length 64 samples (256 ns) 256 samples (128 ns)
Maximum segment length Standard memory size 512 MSa 512 MSa
Option BBM 2 GSa 4 GSa
Maximum number of segments 65,536 65,536
Minimum memory allocation 256 samples or 1 kbyte blocks 256 samples or 1 kbyte blocks
Minimum quantums
1
1 sample 32 samples
Sample clock
Standard clock rate Option BB1 or BB2
Sample rate 250 MSa/s 250 MSa/s and 2 GSa/s
RF modulation bandwidth
Clock rate Bandwidth
250 MSa/s (standard) 200 MHz
2 GSa/s (Opt BB1) 1.6 GHz
2, 3
2 GSa/s (Opt BB2) 400 MHz
3
Triggers
Source External, trigger key, external, remote SCPI trigger over LAN or USB
External trigger inputs Triggers 1–2: SMA rear–panel connectors
Triggers 310: SMB rearpanel connectors
Trigger In: SMB rearpanel connector
All trigger ports have 4 ns input delay resolution
External polarity Negative, positive
Types Single, Continuous free run, Continuous trigger and run
1. A quantum is the minimum number of samples needed to describe a waveform segment.
2. At band crossings at 24, 28.5, 32, 36, and 40 GHz, bandwidth is limited to 800 MHz.
3. Full bandwidth applies for center frequencies > 1.2 GHz.
Page 21
Find us at www.keysight.com
Internal Baseband Generator (Continued)
Markers
Number of markers Markers 1–2: SMA rear–panel connectors with 78.125 ps output delay resolution
Markers 310: SMB rearpanel connectors with 78.125 ps output delay resolution
PRCN Marker Out: SMB rear–panel connector with 10 ps output delay resolution
Marker Out: SMB rear–panel connector with 4 ns output delay resolution
Connector polarity Negative, positive
Remote Programming
Interfaces USB 2.0, 1000BaseT LAN, 10GB Ethernet
Keysight I/O libraries Keysight’s IO Library Suite helps you quickly establish an error–free connection between your
PC and instruments, regardless of the vendor. It provides robust instrument control and works
with the software development environment you choose.
General Specifications
Power requirements 350 W typical, 400 W maximum
Operating temperature range 0 to 50 ˚C
Storage temperature range 40 to 70 ˚C; during storage below –20 ˚C, instrument states and waveform data may be lost.
Altitude 0 to 3000 m (10,000 ft)
Humidity Type tested, 95% relative humidity at 40 °C decreasing linearly to 50% relative humidity at 50 °C.
Environmental testing Samples of this product have been tested in accordance with the Keysight Environmental Test
manual and verified to be robust against the environmental stresses of storage, transportation,
and end–use. Those stresses include but are not limited to temperature, humidity, shock,
vibration, altitude, and power line conditions. Test methods are aligned with IEC 60068–2 and
levels are similar to MILPRF–28800F Class 3. Phase noise specifications are not warranted in a
vibrating environment.
ISO compliant This family of signal generators is manufactured in an ISO9001 registered facility in
concurrence with Keysights commitment to quality.
EMC Conforms to the immunity and emission requirements of IEC/EN 613261 including the
conducted and radiated emission requirements of CISPR Pub 11/2009 Group 1, Class A.
Storage Memory is shared by instrument states and waveform files.
The solid–state drive initially holds at least 512 GB of free space.
Security Display blanking
Memory clearing functions (See Application Note, Security Features of Keysight Technologies Signal
Generators, part number E440090621).
Removable Solid State Drive (SSD) with all user data.
Self–test Internal diagnostic routine tests most modules in a preset condition. If node voltages are within
acceptable limits, then the module passes the test.
Weight 17.2 kg (38.0 lb) net
24.0 kg (52.8 lb) shipping
Dimensions 103 mm H x 426 mm W x 559 mm D (4.05” H x 16.8” W x 22.0” D)
Height and depth dimensions include bottom and rear panel feet.
Rack mounting height: 2U (89 mm or 3.5”)
Recommended calibration cycle 12 months