User-Manual-NeoDen-IN6-Reflow-oven.pdf - 第6页

4 case of causing any accident. 4.3 Status of Indi cators There is a green ba r i ndicator at the PCB entrance t hat i ndicates whether the temperature i n all zones has r eached the set temperature. This i ndicato r lig…

100%1 / 16
3
3.3 Pedestal
4. Installation Instruction
4.1 Power Supply Connection
IN6 is used in 110V/220V single-phase connection mode and is connected according to the
user environment. Wires connection method is shown as picture. L stands for the live wire, N
stands for the zero wire, and E stands for the ground wire, connect to the 220V (110V) power
supply. According to the wiring requirements, the L should be connected to one live wire, and
the N should be connected to one zero wire; the E should be connected to one ground wire
properly
4.2 Installation Attentions
♦Power supply requirement:110V/220V
♦For desktop reflow oven, should be working on workbench, don’t suggest to use wooden
material
♦The machine should be set in standard SMT workshop, stay away from flammable and
explosive if couldn’t meet previous requirements.
♦Exposed wire harness should be well protected, prohibit to expose at the passage or flue in
4
case of causing any accident.
4.3 Status of Indicators
There is a green bar indicator at the PCB entrance that indicates whether the temperature in all
zones has reached the set temperature. This indicator lights up when the actual temperature of
all zones reaches the set temperature.
4.4 Operation instructions
♦ Power-on
Turn the red power switch to the ON position and the machine starts.
♦Transfer chain speed setting
Tap the speed parameter on the screen and press the Up/Down button to set the appropriate
transfer chain rotation speed. When the speed is set, the time required to transport a PCB at this
setting speed is displayed on the right side of the screen.
♦Temperature zone setting
Tap the temperature parameter on the screen and press the up/down buttons to set the
temperature. Black is “the set temperature”, and orange is “the real-time temperature”.
♦Save and Usage of speed and temperature settings
After setting the transfer chain speed and the temperature of each zone, you could press the
SAVE button to save the setting parameters of the transfer chain and the zone temperature.
When the SAVE button is pressed, it will enter the TAB interface. Click on a TAB, then you
Speed setting
Time required
to transport a
PCB
Temperatur
e setting
Power switch
5
can use the "<<<", ">>>" "Up" and "Down" buttons to change the TAB name, long press OK
to save these parameters to this TAB.
When you would like to call the previously saved speed and temperature of the transport chain,
click the LOAD button on the screen to enter the TAB interface, click the TAB name, and then
click the CONFIRM button to load the speed and temperature settings of the transport chain.
♦Start or stop heating
Press the OK button in the main interface, the machine will switch from STANDBY state to
WORKING state, and begin to warm up.
If you need to switch from WORKING state to STANDBY state, just press the OK button in
WORKING state.
♦Temperature curve
Connect the temperature sensor to the TEMP SENSOR connector, attach the temperature
sensor to the PCB, and then click the “Restart” button on the Graph interface after PCB is
put into the oven to get the temperature curve.
Working State
Real-time
Power size
Real time temperature
of heating unit
PCB real time temperature