00197726-12_VB_SE3.11_DE_EN.pdf - 第21页

SIPLACE Explorer from 3. 11 (R 20 -2) Ausgabe 11/20 20 Edition 21 of 44 ● The following restrictions a pply to the SMA pages listed below, if no boards are placed at the last station in the production lin e: ● Machine Na…

100%1 / 44
SIPLACE Explorer from 3.11 (R20-2) Ausgabe 11/2020 Edition
20 of 44
4.8 Existing Restrictions
SIPLACE Explorer has the following restrictions:
Restriction due to NPI mode
SIPLACE Explorer is unable to use data from SIS for boards which are marked as "SA" (stand-alone).
This means that the following information is not available for boards marked with "SA":
Component name
Component shape
Feeder type
The following pages show limited data due to the "Stand-alone" mode:
Pickup reliability
Pickup overview
Reject volume
Status transitions
Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment" is
installed) can monitor five production lines with up to 20 stations.
Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer Runtime Environment is
installed) can monitor one production line with up to 7 stations.
For performance reasons, we recommend that you do not generate reports for all websites and report
types at once. Try to run the report generation at a time when there is no production operation e.g. at
the weekend.
The system time on the connected machines and that belonging to the SIPLACE Explorer must be
synchronized. SIPLACE machines require the installation of TimeSync, which is included on the
Support Media provided with the delivery.
If partially placed boards are removed from the SIPLACE machine, without specifying this termination
in the station software and removing them via the output conveyor, these boards will not be recorded
by the OIS and SIPLACE Explorer systems. In this case, the station software is not able to generate
the data set needed to record the boards. This restriction applies to all available versions of the
station software.
If you need to terminate board placement, always proceed as follows:
Terminate the board at the station software interface.
Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
SIPLACE Explorer from 3.11 (R20-2) Ausgabe 11/2020 Edition
21 of 44
The following restrictions apply to the SMA pages listed below, if no boards are placed at the last
station in the production line:
Machine Navigator:
OLE value will not be shown (N/A).
OLE / OEE Overview:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be shown
correctly.
Overall Equipment Efficiency by station diagram: station data is not shown correctly for
stations which do not place boards.
OEE Analysis:
Table: Values for performance and availability will not be shown correctly for production lines and
stations which do not place boards.
Overall Equipment Efficiency diagram comparison diagram: Values for OEE, performance
and availability will not be shown correctly for the production line.
Due to a restriction from the Microsoft DNS service, the name of the computer on which Tomcat is
installed must include no special characters, in particular no underscore (_). If the name does include
these characters, it will not be possible to display the website.
SIPLACE Explorer from 3.11 (R20-2) Ausgabe 11/2020 Edition
22 of 44
5 Installation
For detailed information about the installation and configuration process, refer to the document "SIPLACE
Explorer Installation and Configuration Manual". This includes a description of the installation process via
the install shield wizard and details of manual configurations to be performed.