00197702-04_VD_SIPLACE-OIB-4.3_EN.pdf - 第25页

Version Descript ion SIPLAC E OIB 4 . 3 05/201 6 E dition 25 7 Functio ns in SIPLA CE OIB Monit oring S erv ice A dapter The f unctions of the SIP LACE OIB Monitor ing Ada pter are • Online Stat ion E vents • Board sum m…

100%1 / 37
Version Description
SIPLACE OIB 4.3 05/2016 Edition
24
6.5 Checking for Setup Center Availability
General
The SIPLACE OIB Setup Center Adapter is a service that will be started when the computer starts and
Setup Center is a GUI application. When SIPLACE Setup Center is closed no material control events are
forwarded to SIPLACE OIB. If the information flow is critical the adapter can check the communication to
Setup Center and trigger an escalation email for the disconnected communication.
Configuration
By default the installation is configured NOT to check for maintained connection.
It can be adjusted in the oib section under configuration->oib in the config files in the installation directory.
<siplaceSetupCenter factoryLocation="TEST.TEST.TEST"
setupCenterSCIPortOut="8001" setupCenterSCITimeOut="60000"
setupCenterPerformProductionEvents="true"
setupCenterPerformUnknownEvents="true"
setupCenterUseProductionEventCache="true"
setupCenterUseProductionEventCacheTimeSpan="60"
setupCenterMSMQMessageThreshold="500"
setupCenterMSMQWatchdogActivation="true"
setupCenterMSMQWatchDogCheckTimeSpan="3600000"
setupCenterDisconnectedWatchdogActivation="false"
setupCenterDisconnectedWatchDogCheckTimeSpan="300000">
Changing the value from setupCenterDisconnectedWatchdogActivation to true will enable the check
functions. Changing the value setupCenterDisconnectedWatchDogCheckTimeSpan will change the time in
milliseconds, after which time of being disconnected an escalation email will triggered.
Version Description
SIPLACE OIB 4.3 05/2016 Edition
25
7 Functions in SIPLACE OIB Monitoring Service Adapter
The functions of the SIPLACE OIB Monitoring Adapter are
• Online Station Events
• Board summary with
o Used material
o Identification and Vacuum errors
o Related SIPLACE Pro and Setup data
o Component names
A combined data model including the separated SIPLACE OIS/SIS data in a common structure.
8 Functions in SIPLACE OIB Client API
8.1 Installing Assemblies into the GAC together with a policy file
The OIB Client API installer copies the client side proxy dlls into the global assembly cache (GAC). It also
adds publisher policies to the GAC.
This makes it possible to update the SIPLACE OIB Smart Proxy assemblies at the customer site without
requiring client applications to be recompiled. It enables bringing bug fixes that were done in the proxy dlls
to the customer without touching the applications.
The policy files will redirect the existing application to use the new versions of the Smart Proxy assemblies
in the GAC. The SIPLACE OIB Client API installation will take care that the upgrade of these components
will be performed automatically..
Please see also the chapter “2.7 Upgrading with SIPLACE OIB” in the 00197701-04_IM_SIPLACE-OIB-
4.3_EN.pdf document for a compatibility matrix.
Version Description
SIPLACE OIB 4.3 05/2016 Edition
26
9 Restrictions
9.1 General Restrictions
Due to the dependency of the API to the underlying SIPLACE products, the content and the functionality of
the exposed API depends on the configuration of the overall system. Please see the adapter version
description of the target adapter for details.
9.2 Restrictions for the Line Control Adapter
The SIPLACE OIB Line Control Adapter must be installed on the same computer as the Line Control
Server has been installed.
9.3 Restrictions for all SIPLACE Pro Adapter Versions
All SIPLACE OIB SIPLACE Pro Adapters require an SPI installation of the target version of SIPLACE Pro
on the same machine.
The installation can be implicitly by installing a SIPLACE Pro product like SIPLACE Pro Desk
on this computer or you can explicitly install the interface by starting the SIPLACE Pro Installer and select “SIPLACE
Pro Interface” as the installation type.
9.4 SIPLACE OIB Setup Center Adapter
When operating the SIPLACE OIB Setup Center Adapter together with the XML Import Service it might
happen that the system is not operating properly, when the event log configuration from Windows is not
setup appropriately.
Workaround: Ensure that the Application event log is setup for “Overwrite events when required”
9.5 Setup Center in General
This chapter describes restrictions concerning the whole Setup Center application.
• For all used components, “verification” has to be activated in SIPLACE Pro.
• The setting “Setup Verification System” of a used setup has to be set to “External … System” in
SIPLACE Pro.
• There has to be a line configured in Setup Center.
• Setup Center only works in unique ID mode, ICL mode is not supported by SIPLACE OIB.
Therefore the barcode definitions have to define a barcode with barcode fragment “UniqueId”.
• Table management is supported with restrictions. Table announcement is only possible at the
station on site. Therefore a table has to be announced first manually, before machine control
operations may be executed via Setup Center Interface. Events have no restrictions.
• Quantity printout for ICL mode has to be disabled.
• XML import has to be disabled.