SOM-1623-002.pdf - 第8页

Tg0594-PM-SO 4. Settings for P .C.B. Recognition T est (1) When the [P .E.C. Recog T est] tab is pressed at the “DVC. TEST” sub menu window , the following tab sheet appears. Fig. 3 (2) When the [Lighting Mode] button is…

100%1 / 17
Tg0594-PM-SO
3. Data Setting
0402-002 5
3.2 Camera Offset Data
The gain and level data can be set for each of P.C.B. recognition
lighting modes (PEC Light #1/PEC Light #2).
(1) When the [Camera Offset] tab is pressed on the “Device Offset”
tab sheet, the following tab sheet appears.
Fig. 2
(2) Set the gain and level data for P.C.B. recognition lighting.
For “Camera 3”, the gain and level data items for standard light-
ing are “P.C.B lighting 1 gain” and “P.C.B. lighting 1 level”.
For “Camera 3”, the gain and level data items for the lighting for
ceramic are “P.C.B. lighting 2 gain” and “P.C.B. lighting 2 level”.
(a) When the gain value is decreased, the contrast becomes
larger.
(b) When the level value is decreased, the entire brightness
becomes higher.
Note
Tg0594-PM-SO
4. Settings for P.C.B. Recognition Test
(1) When the [P.E.C. Recog Test] tab is pressed at the “DVC. TEST”
sub menu window, the following tab sheet appears.
Fig. 3
(2) When the [Lighting Mode] button is pressed, the following display
appears.
Fig. 4
(3) When the [PEC Light #2] button is pressed, the color of the
button is turned to be yellow and the lighting for black light is
selected.
(4) When the [Return] button is pressed, the [P.E.C. Recog Test] tab
sheet is returned.
4. Settings for P.C.B. Recognition Test
0402-002 6
Tg0594-PM-SO
5. “Camera X/Y Origin” Tab
Using this tab, the P.C.B. recognition camera position adjustment and
focus adjustment are performed.
This tab sheet is for service personnel.
(1) When the [Camera X/Y Origin] tab is pressed at the “UNIT ADJ.”
sub menu window, the following tab sheet appears.
Fig. 5
(2) Press the [Camera ID] button and then press the [P.E.C. Recog]
button for adjustment setting.
5. “Camera X/Y Origin” Tab
0402-002 7
Note