Retrofit instructions: SIEMENS conveyor interface for the SIPLACE HF series / X-series / D3
06/2006
11
2 Retrofit instructions:
SIEMENS conveyor interface on the
SIPLACE HF-series / X-series / D3
2.1 Description of the functions
The SMEMA conveyor interface is used as standard from the SIPLACE HF onwards. 2
However, it is generally a good idea to use the "SIEMENS interface" when incorporating a SI-
PLACE HF into a line with other (older) Siplace platforms, otherwise the existing machines will
also have to be retrofitted with a SMEMA interface. 2
If the customer still wishes to have a SIEMENS interface, then the relevant interface cable:
00303636-xx - "SIPLACE - SIPLACE connecting cable“
will have to be ordered and the conveyor control TSP 301 will have to be reconfigured. 2
2.2 Parts required
2.2.1 Retrofit kit
2.2.2 Tools and consumables required
– Set of hexagon socket spanners
– Cable clips
– Cable ties.
SIPLACE - SIPLACE connecting cable
Part no.: 00303636-xx

Retrofit instructions: SIEMENS conveyor interface for the SIPLACE HF series / X-series / D3
06/2006
12
2.3 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.3.1 Definitions
2
2
Caution 2

Retrofit instructions: SIEMENS conveyor interface for the SIPLACE HF series / X-series / D3
06/2006
13
2.4 Preparatory work
: Switch the placement machine off at the main switch.
2.5 Retrofit
: To connect the Siemens interface cable and reconfigure, open the conveyor control above the
pneumatic unit and pull out the control.
You can then run the cable from the inside of the machine and through the conveyor control
terminal box.
: Connect the interface cable for each conveyor track to the conveyor control according to the
type of interface and configure it.
2
Incorrect configuration will cause a short-circuit, and thus damage the conveyor control. You must
therefore check your settings again before switching the placement machine on again. 2
2
X
3
X
4
J
2
J
1
X1
X2
V
erlegung der
Siem ens
Schnittstellenka
SM EM A
Schnitt-
stellen
Siemens inter-
face cable
routing
SMEMA
interfaces