10
5.2.3 To Change Pressure Unit Display
Note: The default pressure unit is PSI. To change pressure unit to BAR,
follow the instructions below.
1. Touch the Setup icon to enter the setup screen
2. Press the “BAR” icon to change pressure unit to BAR
3. Touch the X icon to save and exit
5.2.4 Manual/Purge Dispense Cycle Setting:
1. Touch the Purge icon to select purge cycle.
The Purge icon will turn to green color.
2. Press and hold the foot switch to activate the purge dispense cycle.
Alternately, touch and hold the Run icon on the display to activate the
purge dispense cycle.
27
18. Go to the setup screen of the controller and touch the “Remote Server”
icon
19. Enter the Server IPv4 address recorded in step #11 into Remote IP address box
20. Touch the green check mark icon to save
21. The controller is now connected to the webserver site.
26
13. Go to any computer and open any web browser
14. Type in:
http://localhost:8090/ then touch the enter button
You are now in the webserver site. The below screen will be displayed:
15. Click the “Login” button
16. Enter “admin” in the Login box
17. Enter “1001” in the Password box
11
5.2.5 Automatic Dispense Cycle Setting:
5.2.5.1 Timed Mode
1. Touch the “Timed” mode icon to set the dispense time.
The icon will turn to green color.
2. Touch the “Dispense” icon to enter the setup screen
3. Touch the Up and Down arrows to set the desired dispense time
4. Press the check mark icon to save and exit
Note: if suck back is needed, touch the “Reverse” icon to
setup motor reverse time
5. Press the foot switch to activate the “Timed” dispense
cycle. Alternately, touch the Run icon to activate the
“Timed” dispense cycle
Note: The unit has an “Interrupt” mode feature. In this mode, the
“Timed” dispense cycle can be disrupted if the foot switch is released
and resumed when the Foot Switch is depressed again.
6. Touch the “Interrupt” icon to activate “Interrupt” mode.
The icon will turn to green color.
12
5.2.5.2 Volume Mode
1. Touch the “Setup” icon to enter the setup screen
2. Touch the “Volume” icon to switch to volume mode
3. Press the X icon to save and exit
Note: To switch back to time mode, touch the “Timed” icon
4. Touch the “Dispense” icon to enter the setup screen
5. Touch the Up and Down arrows to set the dispense volume
Note: if suck back is needed, touch the “Reverse” icon to setup
reverse volume
25
9. Type: “set ZONEINFO=C:\iot\timezone.zip” then touch the “Enter” button
10. Type: “ipconfig” then touch the “Enter” button
11. Record the Server IPv4 address show in the “IPv4 Address” line on the above
screen; For this example, the Server IP address is: 172.16.40.91
This address will be entered in the controller screen later.
12. Type: “.\portal” then touch the Enter button