7. Software checks preconditions and displays
status of necessary tools.
Click Start to continue.
8. Calibration has started.
9. Calibration has finished.
Click Accept to approve measurement.

5 Placement Heads
5.2 C&P20 P/M2 Head
118 Technical Training SIPLACE TX-Series 10/2016
5.2.8 Analyse
5.2.8.1 Error General Information
Check Error Information from "Help", to define which kind of problem has occurred.
1. Error Number
2. Possible cause and solution
The main causes of error during production are:
●
Vacuum error
●
Z Axis problem
●
DP Axis problem
●
Nozzle change pick up/reject problem
●
Placement quality issue
Use the charts below during the training to assist with trouble shooting.

5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 119
5.2.8.2 Vacuum Error