5 Placement Heads 5.2 C&P20 P/M2 Head 126 Technical Training SIPLACE TX-Series 10/2016 Maintenance task Twin Interval Equipment required Exchanging the aperture ring (vacuum pump) Workflow 2 ● Cleaning Wipe, KM-Wipe …

100%1 / 266
5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 125
No. Code Error Description Possible Cause Action
9 30524 Cannot reference DP
axis, segment:
DP drive defect
Inspect DP drive and
replace it if necessary
Check error chain
messages
10 30573 Skipping segment after
positioning error,
segment:
DP drive high
temp
DP drive defect
Try to enable relevant DP
drive, Inspect DP drive and
replace it if necessary
Check error chain
messages
11 30624 Nozzle scan failed
Dirty nozzle
Air kiss too low
Inspect nozzle and replace
it if necessary
Check error chain
messages
Check air kiss circuit
34401 Cannot scan nozzle
33368 Nozzle scanning
unsuccessful
5.2.9.2 Maintenance
Maintenance task Twin Interval Equipment required
Cleaning the return cylinder Workflow 2
Cleaning Sticks
Universal placement head mounting rack
Cleaning the Z Axis Workflow 2
Anti-static tweezers, Bernstein 5-192
Torque Screwdriver ESD 1,0-5,0 Nm
Hexagon Socket Head CAP Screw Driver
Universal placement head mounting rack
silicone hose D12 L20mm
Allen key insert - 2,5
Lubricating the DP segment
guidance
Workflow 2
Cleaning Wipe, KM-Wipe
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
Cleaning Sticks
Multipette M4
Combitips advanced 0,1 ml blue
Lubricating the Z Axis linear
guidance
Workflow 2
Cleaning Wipe, KM-Wipe
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
Cleaning Sticks
Universal placement head mounting rack
Multipette M4
Combitips advanced 0,1 ml blue
silicone hose D12 L20mm
Lubricating the C&P20P DP
drive bearing
Workflow 2
Cleaning Wipe, KM-Wipe
Klueberalfa DH 3-100, 50ml (black)
Cleaning Sticks
Universal placement head mounting rack
Multipette M4
Combitips advanced 0,1 ml black
Cleaning the DP reflection
area
Workflow 2
Isopropanol
Cleaning Sticks
5 Placement Heads
5.2 C&P20 P/M2 Head
126 Technical Training SIPLACE TX-Series 10/2016
Maintenance task Twin Interval Equipment required
Exchanging the aperture ring
(vacuum pump)
Workflow 2
Cleaning Wipe, KM-Wipe
Universal placement head mounting rack
Torque Screwdriver ESD 0,1-0,6 Nm
Allen key insert wiha - 2,5
Cover pre-assembled C&P20P
Orifice plate pre-assembled C&P20 P
Cleaning and lubricating the
race way
Workflow 2
Lamora D 220
Cleaning Sticks
silicone hose D12 L20mm
Torque Screwdriver ESD 0,1-0,6 Nm
Allen key insert wiha - 2,5
Cover pre-assembled C&P20 P
Cleaning the component
sensor
Workflow 2
Isopropanol
Cleaning Sticks
Universal placement head mounting rack
Protective cover CO sensor C&P20 P
Replacing the filter discs Workflow 2
Universal placement head mounting rack
Filter disc removal device /C&P20 P
Filterdisc kpl. C&P20 P
Nozzle 4245 Calibration nozzle
Remove maintenance label,
clean this area and attach
new label with actual date
Workflow 2
Cleaning Wipe, KM-Wipe
Isopropanol
Maintenancelabel C&P20 P 10 pcs.
CD-marker edding 8400
Point Pliers 140mm OVAL
For detailed information refer to the Maintenance Job Card for C&P20P Heads.
5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 127
5.2.10 Excercise: C&P20 P Head
1. During reference run the difference between open/close vacuum values for segment 2
is too low, what could be the possible reason?
A PRV is defective.
B Holding circuit vacuum is soiled.
C The nozzle soiled or wrong type.
D Holding circuit vacuum measurement board is defect.
2. Which of the following describes best the function of the component sensor?
A To measure the nozzle height.
B To monitor the presence and/or component height after pickup and before placement.
C To determine Z Axis movement.
D All of the above.
3. Which of the following is false?
A The function of the retract unit is to prevent the Z Axis from sliding down and getting dam-
aged after power off
B The Z Axis end signal is triggered by bottom light sensor, no matter what placement mode
for CPP Head.
C The function of the component camera is component recognition and to determine the exact
position of component on nozzle
D The function of the PRV is to supply vacuum and air kiss during Pickup/Place process.
4. What are the differences between C&P20 P and C&P20 M2
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………