00197717-02_VB_Traceability4.1_DE_EN.pdf - 第28页
Requirements Optional Hardware Requirements 28 SIPLACE Traceability 4.1 3.3 3 . 3 O p t io n a l H a r d w a r e R e q u ir e m e n t s Optional Hardware Requirements ▪ Splice sens or – For X feeders: Hardware insta lla …

Requirements
Software Requirements
SIPLACE Traceability 4.1 27
3
3 Requirements
Requirements
3.1
3.1 Software Requirements
Software Requirements
To run the Traceability 4.1 system, you must install the following software:
▪ SIPLACE Pro 12.1 (recommended), 12.0 (compatible)
▪ Setup Center 7.1 (recommended), 7.0 (compatible)
▪ SIS 12.1 (recommended), 12.0 (compatible)
▪ Trace Service 4.1
▪ Trace Monitor 4.1 (optional) with SIPLACE Studio
▪ Station software:
– 407.05 (SIPLACE 80 F4, F4-6, S20; F5, F5 HM, S23)
– 505.05 SP2 (SIPLACE S25 HM, S27 HM, HS50, HS 50+, HS60, HF, HF3)
– 605.03 SP2 (SIPLACE X2, X3, X4; D1, D2, D3, D4)
– 705.x (SIPLACE X2, X3, X4, X4I, SX1, SX2, SX4, DX1, DX2, DX4)
– 706.0 (SIPLACE X2, X3, X4, X4I, SX1, SX2, SX4, SX1 V2, SX2 V2, DX1, DX2, DX4)
– 706.1 (SIPLACE X2, X3, X4, X4I, SX1, SX2, SX4, X4i S, X4 S, X3 S, SX1 V2, SX2 V2, DX1,
DX2, DX4)
– 707.xx (SIPLACE X2, X3, X4, X4I, SX1, SX2, SX4, X4 Si, X4 S, X3 S, X2 S, X4 S micron, X4i S
micron, SX1 V2, SX2 V2, DX1, DX2, DX4)
– 708.xx (SIPLACE X2, X3, X4, X4I, SX1, SX2, SX4, X4 Si, X4 S, X3 S, X2 S, X4 S micron, X4i S
micron, SX1 V2, SX2 V2, DX1, DX2, DX4)
3.2
3.2 Time Sync
Time Sync
To ensure that you can trace board production data properly at a later date, it is important that all systems
involved have synchronized time keeping. The individual times in the various systems can be automat-
ically synchronized with the SIPLACE Time Sync tool.
SIPLACE Time Sync is a client server application, which helps to synchronize the time at all SIPLACE
machines and all traceability or line computers (client) via the SIPLACE Pro computer or a central time
server (server). Time Sync is installed and configured on one particular computer as a time server and
on one or more other computers as a client.
The SIPLACE Pro line computer has proven to be an ideal time server.
NOTICE
Time Sync
After installing the Time Sync server and Time Sync client, check the settings for "Time Sync"
and correct the times where necessary, at the Time Sync client.
The current Time Sync software and software instructions can be found on one of the Support
Media DVDs (item no: 00388693-xx or 00388694-xx), supplied with each software product.

Requirements
Optional Hardware Requirements
28 SIPLACE Traceability 4.1
3.3
3.3 Optional Hardware Requirements
Optional Hardware Requirements
▪ Splice sensor
– For X feeders: Hardware installation only see also "Job Guide Feeders 8-88 mm X" (item no:
00194487-xx) or"Service SIPLACE X Feeder Care (item no 00196601-xx (German) or
(0019602-xx (English))"
– For S feeders: only available for machine versions 407 and 505
Hardware installation only (table controller V2.0; Hub V2.31)
see also “Retrofitting instructions Splice Sensors 8 - 72 mm” (item no: 00193365-xx)
▪ Board barcode reader: in accordance with the machine type:
– see "PCB Barcode Assembly Instructions" (item no.: 00193891-xx)) for hardware installation and
software configuration via the CLV barcode reader software at SIPLACE F/S/HS/HF/X and D se-
ries machines
– see "PCB Barcode Assembly Instructions for SIPLACE SX1/SX2" (item no.: 00196625-xx) for
hardware installation and software configuration of barcode readers at SIPLACE SX1/SX2 se-
ries machines
▪ Reading the PCB barcode:
– with internal PCB camera (licensed required and dependent on station software)
– with an external scanner
NOTICE
Splice sensors
Splice sensors for X feeders are available for X and SX series machines only.

System Requirements and Software Components
System Requirements for SIPLACE Traceability
SIPLACE Traceability 4.1 29
4
4 System Requirements and Software Components
System Requirements and Software Components
4.1
4.1 System Requirements for SIPLACE Traceability
System Requirements for SIPLACE Traceability
4.2
4.2 Configuration
Configuration
In order to establish the connection to the station computer, you need to install SIPLACE Trace Server
in the SIPLACE LAN. The installation options vary according to your network configuration and are as
follows:
1. SIPLACE Trace Service on one computer
This option requires that all SIPLACE Pro computers are available in the same LAN segment.
2. SIPLACE Trace Service on each line server
This option needs to be selected if the SIPLACE Pro computers are in different line-specific LAN seg-
ments.
3. SIPLACE Trace Monitor
SIPLACE Trace Monitor is installed as part of SIPLACE Studio and opened as a module via SIPLACE
Studio.
The following requirements need to be fulfilled:
1. Each Trace Service configured at the factory with the export option Database must be able to access
the central SQL server, on which the traceability database is installed.
2. The SQL server with the database is on computers in the same LAN segment.
NOTICE
System requirements
The system requirements (supported operating system and database variants) and an over-
view of mutually compatible products can be found in the Assembly Instructions SIPLACE Sup-
port Media, item no [00197214-xx].
NOTICE
Station based traceability
For machine-based traceability, the SIPLACE placement machines must be equipped with the
options "Setup verification" and "Traceability".
NOTICE
System requirements
The system requirements (supported operating system and database variants) and an over-
view of mutually compatible products can be found in the Assembly Instructions SIPLACE Sup-
port Media, item no [00197214-xx].
NOTICE
SQL server
For a detailed description of how to install the SQL servers, refer to the Assembly Instructions
(item no. 00196824-xx (English)), on Support Media DVD 1. The SQL server itself is not part of
the Support Media DVDs.