Existing Restrictions Technical Restrictions SIPLACE Traceability 4.1 33 5.2 5 . 2 T e c h n ic a l R e s t r ic t io n s Technical Restrictions ▪ Network connection To enable SIPLACE Trace Servic e to import the traceab…

Existing Restrictions
Traceability
32 SIPLACE Traceability 4.1
▪ The length of the setup name is limited to 20-50 characters, i.e. only the first 20 to 50 characters will
be taken into account during setup changeovers.
▪ The unique ID for a packaging unit may have a maximum of 40 characters.
▪ If you change the configuration of the Traceability system the SIPLACE line has to be empty. Other-
wise Traceability data may be incomplete.
▪ Station based and line based traceability cannot run simultaneously in the same line.
▪ If a station is part of several lines (SIPLACE Pro configuration), there are the following restrictions
for line based traceability:
– Only one of the lines may be active at the same time.
– If an external PCB barcode reader is allocated to more than one line then the PCB barcodes are
assigned to the line which is active in Trace Service. If there are multiple lines active with the
same external barcode reader, Trace Service will issue an error message. Traceability data can
not be reliably generated in this case.
▪ In case of line based traceability the sequence of the boards may only be changed (e.g. by a pro-
ductivity lift) if there are external PCB barcode readers in front of AND at the end of the line.
▪ The option "Remove unused charges" in the TraceService Monitor requires that you perform forced
setup verification for all the lines for which traceability data are to be generated in "line-based" mode.
If a rear barcode scanner was configured, it should not be positioned directly behind the last
SIPLACE placement machine; there should be a time lag with respect to the last placement (e.g. be-
hind the furnace). Otherwise, Traceability data may be incomplete.
▪ The "Station-based traceability" mode with the "Create one combined Traceability data packet for
each board side" option activated entails the following limitations:
– At least 2 stations must be configured in the respective line.
– Each station in the line must be able to produce traceability data with PCB barcode (either via
PCB barcode scanner or via Whispering option).
– If the PCB label is placed, it must be placed at the first station in the line.
– The "MachineID" attribute is not available in the combined traceability file.
For 407
▪ When using a synchronous dual conveyor, traceability data can only be generated to a limited de-
gree. The restriction is based on the fact that both boards are seen as one panel and that the trace-
ability data is therefore stored in one data package. The board barcode used is always the barcode
read at conveyor 1.
Station software Max. length of setup names
407 20 characters exc. path
505 50 characters exc. path
605 256 characters inc. path
70x 256 characters inc. path
NOTICE
Station and line name
The station name must be unique in the line. The line name must be unique throughout the
traceability system.
Existing Restrictions
Technical Restrictions
SIPLACE Traceability 4.1 33
5.2
5.2 Technical Restrictions
Technical Restrictions
▪ Network connection
To enable SIPLACE Trace Service to import the traceability data from stations with station software
<70x, you need to configure the relevant network connections. The non-availability of configured im-
port paths and network connections is recorded in the log file.
▪ We recommend that you limit the size of the Trace database to 20 GB. If the database has reached
this size, it should be archived in a backup and the production should be continued with a newly cre-
ated Trace database.