18 WF 4 TX-Series V2 Maintenance Calibrate the maintained TH 13 min 1 / 9 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e …

www.asm-smt.com

18 WF 4 TX-Series V2 Maintenance Calibrate the maintained TH 13 min 1 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
1 Open the cover. 2 Insert the calibration tool into the pocket. 3 Close the cover.
4 Click on "Settings and options". 5 Click on "User settings". 6 Click on "Machine service".

18 WF 4 TX-Series V2 Maintenance Calibrate the maintained TH 13 min 2 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
7 If you mount the same heads continue
with step 23.
8 Click on "Check sensor and options". 9 Click on "Check sensors function of spe-
cific components".
10 Click on "Twin head". 11 Click on "Check positions and functions of
the Z-Axis".
12 Click on "Zero correction data".