80S-2080F480F4-680F5 User’s Manual.pdf - 第657页

11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s M anual 11.9 GEM Interface Edition 03/98 from Software Version SR.404.xx 11 - 60 11.9.2 Operation 11.9.2.1 Main Menu with GEM Interfac e Option Fig. 11.9. 2 …

100%1 / 744
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options
Edition 03/98 from Software Version SR.404.xx 11.9 GEM Interface
11 - 59
11.9 GEM Interface
11.9.1 General Comments
GEM => Generic Equipment Model
SECS-II => Semiconductor Equipment Communication Standard, Part 2
Host => Communications computer
With the GEM / SECS-II interface it is possible to control a SIPLACE station using any host which is compati-
ble with GEM. However, the SIPLACE station must be left connected to the line computer to allow the
machine, set-up and cluster data to be programmed and loaded into the station. The SIPLACE station packs
these data into a placement program and makes this available to the host for reading. During operation, and
depending on the control mode, the host or the line computer provides the SIPLACE station with the neces-
sary machine, set-up and cluster data.
Fig. 11.9.1 General view of overall structure
Host
GEM
Line computer
LAN
SIPLACE 80 S-20
GEM
LAN
SIPLACE 80 F
4
SIPLACE 80 F
4
-6
SIPLACE 80 F
5
GEM
LAN
SIPLACE LAN
Customer‘s LAN
11 Station Extensions/Options SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
11.9 GEM Interface Edition 03/98 from Software Version SR.404.xx
11 - 60
11.9.2 Operation
11.9.2.1 Main Menu with GEM Interface Option
Fig. 11.9.2 Main view with GEM interface option
- Key to Fig. 11.9.2
1 To the Control mode menu 2 To the GEM defaults menu
3 To the GEM interface menus 4 The current control mode is displayed here.
5 GEM status display
2 31 4 5
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 11 Station Extensions/Options
Edition 03/98 from Software Version SR.404.xx 11.9 GEM Interface
11 - 61
11.9.2.2 Control Mode
The control mode specifies who is supplying the station with the placement data it requires.
In the main view, select the Options menu and then click on Control mode.
The following selection box appears.
Fig. 11.9.3 Control mode
Save what you have entered by pressing the OK button.
l Stand-alone (for testing only)
If a cluster is specified at the SIPLACE station, all necessary data will be loaded from the hard disk of the
station computer.
All of the data required must be located on the station computer‘s hard disk.
l GEM host
In this control mode only the host can specify the placement programs.
All of the data required must be located on the host computer.
NOTE
This setting must be set if you wish to load placement programs from the host onto the station computer
under the Load placement program menu. In this connection, see Section 11.9.2.7 "Load Placement
Program"