80S-2080F480F4-680F5 User’s Manual.pdf - 第73页
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 1 Operational Safety Edition 03/98 from SW SR.404.xx 1.7 Emissions and energy efficiency of the MCM 1405 ND monitor 1 - 31 1.7 Emissions and energy efficiency of the MCM 1405 ND mo…
1 Operational Safety SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
1.6 Lock out and tag out procedure when performing any maintenance work or service work Edition 03/98 from SW SR.404.xx
1 - 30
SIPLACE 80S-20/F4/F4-6/F5 User’s Manual 1 Operational Safety
Edition 03/98 from SW SR.404.xx 1.7 Emissions and energy efficiency of the MCM 1405 ND monitor
1 - 31
1.7 Emissions and energy efficiency of the MCM 1405
ND monitor
1.7.1 X-ray radiation
The X-ray radiation generated in the monitor is adequately shielded by the intrinsically safe cathode-ray tube.
The local emissions are less than 1 µS/h (micro-Sievert per hour). The accelerating voltage is limited by the
device to a maximum of 26 kV.
The monitor conforms to the German Directive for protection against harmful X-ray radiation. The X-ray emis-
sions from the monitor conformed to the DHHS Rules 21 CFR, subsection J on the date of manufacture and
to the FCC Rules, part 15.
1.7.2 Efficiency and electromagnetic emissions
The MCM 1405 ND monitor fulfils the conditions for efficiency (to ISO 9241-3) and safety (to EN 60950).
The low-frequency electromagnetic emissions fall below the MPR II guidelines issued by the Swedish Radia-
tion Institute in Stockholm.
1 Operational Safety SIPLACE 80S-20/F4/F4-6/F5 User’s Manual
1.7 Emissions and energy efficiency of the MCM 1405 ND monitor Edition 03/98 from SW SR.404.xx
1 - 32