00198765-02_VD_SSW_713.1_R20-1_EN_DE.pdf - 第13页

Station Software 713.1 (R 20-1) / V ersion Description 05/2020 Edition 13 4.4 Scan Request Dialog – Enhance ments Compatible mode: Complete When performing a s can request for a feeder, it is pos sible to switch between …

100%1 / 68
Station Software 713.1 (R20-1) / Version Description 05/2020 Edition
12
4.3 Configuring Tolerance Values for Resetting the Conveyor Width
Compatible mode: Complete
If the Automatic Width Adjustment option has been activated on the Line Control GUI and the
conveyor width of the lane differs from the width specifications in the recipe (e.g. because it has
been manually changed for maintenance), the conveyor width is automatically reset to the width
specifications from the recipe at the start of production.
But even if the Automatic Width Adjustment option is deactivated, the conveyor width is reset to
the width specified in the recipe at the start of production if the conveyor width has been manually
changed further than a configured tolerance allows. The tolerance values can be specified in the
Tolerance fields under Resetting the conveyor width in the Width settings of the respective
lane. If the Automatic Width Adjustment option is deactivated on the Line Control GUI and you
do not want the conveyor width to be automatically reset at the start of production, you can use the
Deactivate automatic resetting option under Resetting the conveyor width.
Figure 4-2: Configuring tolerance values for resetting the conveyor width
By default, the conveyor width is allowed to differ by 1 mm from the width specifications in the
recipe. The smallest possible value is 0.0 mm (no deviation allowed). Negative values are not
allowed. The biggest possible value is 10 mm.
Restrictions
The station can only adjust the width while no board is in the respective lane.
Station Software 713.1 (R20-1) / Version Description 05/2020 Edition
13
4.4 Scan Request Dialog Enhancements
Compatible mode: Complete
When performing a scan request for a feeder, it is possible to switch between feeder divisions in
the Scan Request dialog.
After clicking the scan request button on the feeder or after ordering a scan request in ASM Setup
Center, the Scan Request dialog opens in the station GUI. In this dialog, you can navigate
between feeder divisions by clicking on the arrow buttons next to the division number.
Figure 4-3: Buttons for navigating between divisions in Scan Request dialog
For easier visibility the number of the currently selected feeder division has been further
highlighted. The division number is now displayed in a bigger font in an extra field and blinks.
Restrictions
The feature is only supported for the following feeder types that have multiple divisions or
channels:
Smartfeeder 2x8mm Xi Splice, item no. [00141499-xx]
Smartfeeder 2x8mm Xi, item no. [00141479-xx]
Station Software 713.1 (R20-1) / Version Description 05/2020 Edition
14
4.5 Monitoring and Logging of Maintenance Status
To improve machine availability and to prevent unplanned machine failures, hardware components
such as the guide cars, guide rails and loose bearings are monitored and, when their service life
setpoints are reached, a detailed error message is issued at the station.
Figure 4-4: Detailed error message for maintenance status
Furthermore, the status bar for monitoring the maintenance status of hardware components is now
divided into different color sections. If certain threshold values are exceeded, the maintenance
status in the progress bar switches to a different color.
Figure 4-5: Example for maintenance status indicated in different colors
For further information, please refer to the Technical Information about the maintenance due status
on SIPLACE machines, item no. [TI2020-03D06].