NPM- TT2 EJ M1EE-MB-13M-0 2 Choose a table ● Choose the table to calibrate. 2 + 1 Head camera XY origin Explains the method for calibrating XY origin of a hea d camera . This operation procedur e is also shared by the 8-…

NPM-TT2 EJM1EE-MB-13M-02
Calibration
13-1-4-2

NPM-TT2 EJM1EE-MB-13M-02
Choose a table
●Choose the table to calibrate.
2
+
1
Head camera XY origin
Explains the method for calibrating XY origin of a head camera.
This operation procedure is also shared by the 8- and 3-nozzle heads.
(The camera angle is calibrated)
Confirm that it has been
successfully completed
+
(The XY origin camera scale is
calibrated)
3
13-2-1
Maintenance
13-2
12
3

NPM-TT2 EJM1EE-MB-13M-02
13-2-2
Confirm the message
6
6
●When you do not save the data
●To cancel
(The screen remains as it is in . )
5
Confirm the message
7
(XY unit moves to the origin)
+
7
Confirm that it has been
successfully completed
4
5
●Perform steps to for the
other table.
1
4
Calibration
4 5