N7201A653E.pdf - 第314页

NPM- TT2 EJ M1EE-MB-13M-0 2 Plane calibratio n XY 9 Prepare for the second plane calibration XY 11 10 Open the safety cover 12 Set the plane calibration jig Maintenance 13-3-1 ① Manually m ove the calibration jig and ali…

100%1 / 502
NPM-TT2 EJM1EE-MB-13M-02
5
Set the plane calibration jig
Manually move the calibration jig and
align the left end of the plane
calibration jig to the left side guide line
on the PCB conveyor upper surface.
(Both on lane 1 and 2. Common in
each PCB flow direction)
Set the reference mark on the plane
calibration jig to the reference rail.
Attach the plane calibration jig to the
reference rail.
Calibration
6
Close the safety cover
7
Servo switch ON
+
8
8
If you cannot set a plane calibration jig,
manually load the PCB from the pre-
process machine and set the jig using
the workbench (please prepare
yourself).
Operator
Guide line
Reference mark
Reference mark
Reference rail
Reference rail
Lane 1
Lane 2
Plane
calibration jig
13-3-1-2
You can also remove the feeder cart
and set a plane calibration jig.
NPM-TT2 EJM1EE-MB-13M-02
Plane
calibratio
n XY
9
Prepare for the second plane
calibration XY
11
10
Open the safety cover
12
Set the plane calibration jig
Maintenance
13-3-1
Manually move the calibration jig and
align the right end of the plane
calibration jig to the right side guide
line on the PCB conveyor upper
surface. (Both on lane 1 and 2.
Common in each PCB flow direction)
Set the reference mark on the plane
calibration jig to the reference rail.
Attach the plane calibration jig to the
reference rail.
13
Close the safety cover
14
15
Confirm the message
+
15
Servo switch OFF
Servo switch ON
Operator
Guide line
Reference mark
Reference mark
Reference rail
Reference rail
Lane 1
Lane 2
Plane
calibration jig
If you cannot set a plane calibration jig,
manually load the PCB from the pre-
process machine and set the jig using
the workbench (please prepare
yourself).
13-3-1-3
Plane calibration XY
(PC size conveyor) 2
You can also remove the feeder cart
and set a plane calibration jig.
(Plane calibration XY is measured on the
front head and rear head, in that order)
(After measurement, the head moves to the
retraction position)
NPM-TT2 EJM1EE-MB-13M-02
16
Confirm that it has been
successfully completed
16
Calibration
17
Confirm the message
(The plane calibration XY data is saved)
When you do not save the data
To cancel
(The screen remains as it is
in )
16
17
13-3-1-4