12 Reinstallation User Manual V 1.15 - P roductivity Lift 12.2 Dismantling Software version V 40. 1 1 Edition 01/2001 80 'LV PDQWOLQ J Pack and transpo rt the uni t after disc onnectin g, power cords, i nterfac…

User Manual V 1.15 - Productivity Lift 12 Reinstallation
Software version V 40.11 Edition 01/2001 12.1 Reinstallation
79
5HLQVWDOODWLRQ
This chapter explains how to reinstall the device. A qualified person or employee (service engi-
neer) may only do this.
127(
For reinstallation, dismantling or disposal the Productivity Lift has to be prepared. For installation
please refer to Installation instruction (Article No.: 00191 967-01).
5HLQVWDOODWLRQ
If the Productivity Lift needs to be removed or moved within a production line, please follow
the instructions below.
1. Position the Top Conveyor in its lowest position using the manual mode and install transport
locks (see chapter 2.5).
2. Position Shuttle Conveyor in its lower position and tighten Mount shaft clamp Figure 2 - 3, Page
14) to secure Shuttle Conveyor.
3. Press the button marked "Stop" on the system control panel.
4. Set the main switch to the "0" position.
5. Disconnect the power supply via the main cable and pack it into the control cabinet.
6. Disconnect any pneumatic energy supply by removing the feed hose. Pack it sensibly into the
system.
7. Remove any transport goods and magazines intended for this purpose from the device.
8. Remove the keys for the key switch located in the control cabinet to bridge the safety switches
of covers and doors.
9. Close and lock all doors and covers.
12 Reinstallation User Manual V 1.15 - Productivity Lift
12.2 Dismantling Software version V 40.11 Edition 01/2001
80
'LVPDQWOLQJ
Pack and transport the unit after disconnecting, power cords, interface cables and compressed
air lines. Please follow the relevant Safety and Transport regulations during this process.
'LVSRVDO
Only "operators" have responsibility for disposal. They must ensure that the system and its oper-
ating supplies are disposed of correctly.
The construction of the system only involved materials that can be easily recycled or are not harm-
ful when destroyed. Dangerous substances are not necessary for either the construction or oper-
ation of the device.
The relevant national legal provisions must be complied with when disposing of the different de-
vice parts.
'LVSRVLQJWKHGHYLFH
Dispose of the device by taking it apart, sorting the parts separately according to material, and
disposing of them accordingly.
The device consists of the following materials:
Frame : steel
Panelling : steel and plastic
Mechanical components : aluminium
Controller : plastics, non-ferrous metals and electronic components

User Manual V 1.15 - Productivity Lift Index
Software version V 40.11 Edition 01/2001
81
,QGH[
$
Address width 1
. . . . . . . . . . . . . . . . . . . . . . . . .42
Address width 2
. . . . . . . . . . . . . . . . . . . . . . . . .42
ALT protection
. . . . . . . . . . . . . . . . . . . . . . . . . . .38
Areas of responsibility
. . . . . . . . . . . . . . . . . . . . . .8
Assembling and installing
. . . . . . . . . . . . . . . . . .27
Attaching safety stickers
. . . . . . . . . . . . . . . . . . .16
Automatic tracking
. . . . . . . . . . . . . . . . . . . . . . .67
&
CAN-Bus
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Cluster module
. . . . . . . . . . . . . . . . . . . . . . . . . .53
Code number
. . . . . . . . . . . . . . . . . . . . . . . 12, 37
Configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Control cabinet
. . . . . . . . . . . . . . . . . . . . . . . . . .24
Convert 2 - 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Convert 4 - 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Conveyor on LF 1
. . . . . . . . . . . . . . . . . . . . . . . .38
Cover open
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Cross module
. . . . . . . . . . . . . . . . . . . . . . . . . . .53
Crushing of fingers
. . . . . . . . . . . . . . . . . . . . . . .16
'
Danger areas
. . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Danger of crushing
. . . . . . . . . . . . . . . . . . . . . . .16
Definitions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Description of interface
. . . . . . . . . . . . . . . . . . . .73
Device
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Device environment
. . . . . . . . . . . . . . . . . . . . . . .8
Disconnecting compressed air supply
. . . . 12, 13
Dismantling
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Disposal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
(
Electrical (CAUTION)
. . . . . . . . . . . . . . . . . . . . .16
Emergency stop
. . . . . . . . . . . . . . . . . . . . . . . . .77
Emergency stopping switches
. . . . . . . . . . . . . .25
Err. width inlet
. . . . . . . . . . . . . . . . . . . . . . . . . . .77
ESD guidelines
. . . . . . . . . . . . . . . . . . . . . . . . . .12
)
Fault belt
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Fault information
. . . . . . . . . . . . . . . . . . . . . . . . 77
Fault lift
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Fault Shuttle
. . . . . . . . . . . . . . . . . . . . . . . . . . . 78
+
Hybrid light barriers
. . . . . . . . . . . . . . . . . . . . . . 67
,
Identity number
. . . . . . . . . . . . . . . . . . . . . . . . . 52
Inappropriate use
. . . . . . . . . . . . . . . . . . . . . . . . 4
Indicator lamps
. . . . . . . . . . . . . . . . . . . . . . . . . 25
Input identity number
. . . . . . . . . . . . . . . . . . . . . 50
Input module
. . . . . . . . . . . . . . . . . . . . . . . . 17, 52
Installation and operation instructions
. . . . . 27, 69
Installation of emergency conveyor
. . . . . . . . . . 28
Intended use of the device
. . . . . . . . . . . . . . . . . 3
Interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Interface 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Interface 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Interface module
. . . . . . . . . . . . . . . . . . . . . . . . 75
Interlock bridged
. . . . . . . . . . . . . . . . . . . . . . . . 77
.
Key switch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
/
Language
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Lift
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Lift 1 not up
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Lift 2 not down
. . . . . . . . . . . . . . . . . . . . . . . . . . 77
List of figures
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .v
Location of the operating instructions
. . . . . . . . . 2
Locking the lift belt
. . . . . . . . . . . . . . . . . . . . . . 13
Locking the upper lift belt
. . . . . . . . . . . . . . . . . 14
LP blocked
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 77