DECAN_S1_Operation_EN.pdf - 第86页
Ch e ck o th e r s and r e plac e e xhaus t e d part s Chap ter 6 Nex t Generation, Multi- Funct ional Placer DE CAN S 1 Ope ra tio n Han db oo k 6-1 3 This Chapter describes the items for which care must be exercised wh…

Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-12
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Arranging Backup Pins > Setting the height of backup pins
Arranging Backup Pins
Check others and replace exhausted parts
2. Setting the height of backup pins
You should set the height of backup pins after securing the
master PCB in the conveyer.(Height of backup pin: 132.3
mm in general)
Step 1.
Set the height of the backup pins in the sides.
Set the height so that the pins are in contact with the sides of the PCB.
Step 2.
Set the height of the backup pins in the central area.
Set the height of the central backup pins so that they are on the same level with
the pins on both sides.

Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-13
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Arranging Backup Pins > Checking the flatness of the PCB
Arranging Backup Pins
3. Checking the flatness of the PCB
Place and secure the PCB in the conveyer. Then, check if
the PCB is flat using a ruler.
Step 1.
Checking the flatness of the PCB in a diagonal direction
Use a ruler to check if the PCB is flat diagonally.
Step 2.
Checking the flatness of the PCB in a horizontal direction
Use a ruler to check if the PCB is flat in three horizontal positions.
Caution
If the PCB is not flat, the parts may not be properly placed. If the
PCB is not flat, reset the height of the backup pins.

Check others and replace exhausted parts
Chapter 6
Next Generation, Multi-Functional Placer
DECAN S1 Operation Handbook
6-14
This Chapter describes the items for which care must be exercised while
using thetape feeder as well as the method to take measures when
parts are exhausted.
Replace exhausted parts > Change the part reel
Replace exhausted parts
Check others and replace exhausted parts
1. Change the part reel
Step 1.
Pull the grip back.
Step 2.
Remove the feeder.
Step 3.
After removing the part reel, install a new reel. (Secure the
reel on the reel brake paying careful attention to the reel
winding direction.)
Step 4.
Open the tape guide referring to the following figure. (Handle
it in the order of the numbers.)
Replace exhausted parts