00197674-01-UM-E-Series-EN-02-2015.pdf - 第301页
User manual SIPLACE E 7 Maintenance From software version SC 708.0 02/2015 Edition 7.1 Safety Inform ation 301 7 Maintenance 7 7.1 Safety Information Please ensure all safety inf ormation in this section. 7 7 PLEASE NOTE…

6 Station extensions User manual SIPLACE E
6.8 Power Supply COT E From software version SC 708.0 12/2014 Edition
300
6
PLEASE NOTE
Connection to the SIPLACE Setup Center
Only one PowerSupply COT E with Change over table is to be connected to SIPLACE
Setup Center for feeder setup.
When using the CAN Bus Cable 03040465-xx with SIPLACE Setup Center, the ter-
minal resistor at the bus system end to the SIPLACE Setup Center must be acti-
vated.The terminal resistor at the bus system end to the PowerSupply COT E and
Change over table must NOT be activated.
The CAN ID for the PowerSupply COT E with Change over table in standalone mode
is 0x0518.

User manual SIPLACE E 7 Maintenance
From software version SC 708.0 02/2015 Edition 7.1 Safety Information
301
7 Maintenance
7
7.1 Safety Information
Please ensure all safety information in this section.
7
7
PLEASE NOTE
Maintenance - Further information
For further information on how to complete the tasks please visit the experience area on
the website: www.e-by-siplace.com
CAUTION
Only qualified personnel
These cleaning and checking tasks may only be carried out by appropriately qual-
ified personnel.
Caution, as used in this user manual, means that slight injury or damage to equipment
may occur if the caution instructions are not followed.
CAUTION
Filter elements
The cleaning and checking intervals given for inspecting and replacing the filter
elements only apply to the specified compressed air quality (see
Section 3.2.4 on
page 103
). If other qualities are used, the intervals should be shortened accord-
ingly.

7 Maintenance User manual SIPLACE E
7.2 Maintenance on Base Machine From software version SC 708.0 02/2015 Edition
302
7.2 Maintenance on Base Machine
7
7
Base machine Every 6
months
Every 12
months
– Checking the Fans on the MGCU
X
– Checking the safety features on machines
X
– Checking and Cleaning/Replacing (if required) the Compressed Air Filter
X
– Cleaning/Replacing the Head Exhaust Air Filter
X
– Greasing and clean the X axis guide bearing
X
– Cleaning the Linear Guides of the X Axis
X
– Grease and clean the Y axis guide bearing
X
– Cleaning the Linear Guides of the Y Axis
X
– Cleaning the X Axis Scale
X
– Cleaning the Y Axis Scale
X
– Cleaning the Protective Covers
X
– Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the
Protective Covers
X
– Replace the loose bearing lubrication system X axis and Y axis (if pres-
ent)
X
– Grease and clean the X and Y axis guide bearing
X
Conveyor Every 6
months
Every 12
months
– Cleaning and Preserving the Conveyor
– Hexagonal shafts
– Linear guide rails
– Ball screws
– Guide shaft
X