00197674-01-UM-E-Series-EN-02-2015.pdf - 第302页
7 Maintenance User manual SIPLACE E 7.2 Maintenance on Base Machine From software version SC 708.0 02/2015 Edition 302 7.2 Maintenance on Base Machine 7 7 Base machine Every 6 months Every 12 months – Checking the Fans o…

User manual SIPLACE E 7 Maintenance
From software version SC 708.0 02/2015 Edition 7.1 Safety Information
301
7 Maintenance
7
7.1 Safety Information
Please ensure all safety information in this section.
7
7
PLEASE NOTE
Maintenance - Further information
For further information on how to complete the tasks please visit the experience area on
the website: www.e-by-siplace.com
CAUTION
Only qualified personnel
These cleaning and checking tasks may only be carried out by appropriately qual-
ified personnel.
Caution, as used in this user manual, means that slight injury or damage to equipment
may occur if the caution instructions are not followed.
CAUTION
Filter elements
The cleaning and checking intervals given for inspecting and replacing the filter
elements only apply to the specified compressed air quality (see
Section 3.2.4 on
page 103
). If other qualities are used, the intervals should be shortened accord-
ingly.

7 Maintenance User manual SIPLACE E
7.2 Maintenance on Base Machine From software version SC 708.0 02/2015 Edition
302
7.2 Maintenance on Base Machine
7
7
Base machine Every 6
months
Every 12
months
– Checking the Fans on the MGCU
X
– Checking the safety features on machines
X
– Checking and Cleaning/Replacing (if required) the Compressed Air Filter
X
– Cleaning/Replacing the Head Exhaust Air Filter
X
– Greasing and clean the X axis guide bearing
X
– Cleaning the Linear Guides of the X Axis
X
– Grease and clean the Y axis guide bearing
X
– Cleaning the Linear Guides of the Y Axis
X
– Cleaning the X Axis Scale
X
– Cleaning the Y Axis Scale
X
– Cleaning the Protective Covers
X
– Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the
Protective Covers
X
– Replace the loose bearing lubrication system X axis and Y axis (if pres-
ent)
X
– Grease and clean the X and Y axis guide bearing
X
Conveyor Every 6
months
Every 12
months
– Cleaning and Preserving the Conveyor
– Hexagonal shafts
– Linear guide rails
– Ball screws
– Guide shaft
X

User manual SIPLACE E 7 Maintenance
From software version SC 708.0 02/2015 Edition 7.2 Maintenance on Base Machine
303
7
7
7
a) This value is for 3 shift operation (7500 hours of operation). Longer intervals can be planned for other operation setups.
Component Docking Unit Every 6
months
Every 12
months
– Function Test of Tape Cutter
X
– Greasing the Tape Cutter
X
– Greasing the Cutting Blade
X
– Greasing the COT Insert
X
– Greasing the Locator Bearing on the Component Trolley for SIPLACE
SmartFeeder E
X
Optical Systems Every 6
months
Every 12
months
– Cleaning the IC and FC Cameras
X
– Cleaning the PCB Barcode Scanner (if availible)
X
Cleaning and Checking tasks
Vacuum pump
Every 6
months
Every 12
months
– Checking/Replacing the Filter Insert
X
a