SITEST for WPC4 General Service Manual SIPLACE WPC4 71 5S I T E S T f o r W P C 4 5.1 General With the help of the functions in the SITEST test program, you can set up and ca librate SIPLACE placement machines. T his man…

100%1 / 102
Calibration and Settings
Other Functions Releasing Axes
70 Service Manual SIPLACE WPC4
4.4.4 Releasing Axes
The axes can be released for test purposes. This means that the servo board is switched off via the
software. The relevant axis can now be moved mechanically.
X Open the SITEST main view and select the function=>
SITEST Axes
.
X Select the required axis in the input area
Axis
.
X In the input area
Functions
select
Control off…
.
X See also SITEST.
4.4.5 Calibrating Reference Fiducials
The WPC4 has two reference fiducials for determining the exact position in the docked SIPLACE
machine. These reference fiducials are automatically approached and measured after docking. If these
reference fiducials are not found, you will need to calibrate them.
X Open the SITEST main view and select the function=>
SITEST Functions
.
X In the input area
Calibrate pickup position
select
Calibration
.
X Follow the instructions as you are guided through the menu. See also SITEST.
NOTE: Calibration required after conversion
X After converting from the changeover table to the WPC4, perform calibration of the reference
fiducial.
SITEST for WPC4
General
Service Manual SIPLACE WPC4
71
5SITEST for WPC4
5.1 General
With the help of the functions in the SITEST test program, you can set up and calibrate SIPLACE
placement machines. This manual explains the individual SITEST dialog boxes for the WPC4. This
documentation refers to SITEST version 603.01.
The data in the dialog boxes, such as times, travel ranges, lengths or folders are only examples and are
not intended for use as references.
The square brackets contain measurements such as [mm] for millimeters, [s] for seconds etc. If there is
a conversion factor in front of this, the value in the square brackets must be multiplied by this figure.
Examples:
90 [0.1 mm] = 9 mm
3000 [0.01m/s²] = 30 m/s².
The "Help" button has the same function in all dialog boxes and will not be included in the following
explanations. This "Help" button opens the online help and shows the help text for the dialog box
currently open.
5.2 Safety Instructions
5.3 Opening the SITEST Interface
The SITEST user interface can be opened as follows from the main view of the station computer user
interface:
Select the icon from the toolbar
or
Open the View menu and select Start SITEST
or
Press the F11 key and acknowledge the dialog box shown with
Yes
.
DANGER: The SITEST program may only be operated by specially trained SIEMENS AG
staff or customer personnel.
X Always observe the general safety instructions in the operating manuals of the respective
SIPLACE machines and the WPC4.
NOTE: The SITEST program can not be opened in the "Operator" access level.
SITEST for WPC4
Closing the SITEST Interface
72 Service Manual SIPLACE WPC4
5.4 Closing the SITEST Interface
The SITEST user interface can be closed as follows:
In the main SITEST view, select the button
or
Open the Mode menu and select Exit
or
Press the Esc key and acknowledge the dialog box shown with
Yes
.
5.5 Selecting Dialog Boxes
The icons in the footer line allow you to switch over between the individual main dialog boxes.
1. Click on this icon to exit SITEST.
2. Opens the dialog box SITEST - Functions
3. Opens the dialog box SITEST - Axes
4. Opens the dialog box SITEST - Settings
5. Opens the dialog box SITEST - Machine data
6. Opens the dialog box SITESTInputs/outputs 1
7. Opens the dialog box SITESTInputs/outputs 2
8. Shows that a WPC is connected to the placement machine.
This last icon is designed for the second MTC tower and is not used in this WPC4 SITEST software.