WPC4 services manual.pdf - 第73页
SITEST for WPC4 SITEST Functions Service Manual SIPLACE WPC4 73 5.6 SITEST Functions Menu field: Info Type: Shows the WP C type. Menu field: Calibrate pickup posi tion X: Shows the calibration value in the X directio…

SITEST for WPC4
Closing the SITEST Interface
72 Service Manual SIPLACE WPC4
5.4 Closing the SITEST Interface
The SITEST user interface can be closed as follows:
In the main SITEST view, select the button
or
Open the Mode menu and select Exit
or
Press the Esc key and acknowledge the dialog box shown with
Yes
.
5.5 Selecting Dialog Boxes
The icons in the footer line allow you to switch over between the individual main dialog boxes.
1. Click on this icon to exit SITEST.
2. Opens the dialog box SITEST - Functions
3. Opens the dialog box SITEST - Axes
4. Opens the dialog box SITEST - Settings
5. Opens the dialog box SITEST - Machine data
6. Opens the dialog box SITEST – Inputs/outputs 1
7. Opens the dialog box SITEST – Inputs/outputs 2
8. Shows that a WPC is connected to the placement machine.
This last icon is designed for the second MTC tower and is not used in this WPC4 SITEST software.

SITEST for WPC4
SITEST Functions
Service Manual SIPLACE WPC4
73
5.6 SITEST Functions
Menu field: Info
Type: Shows the WPC type.
Menu field: Calibrate pickup position
X: Shows the calibration value in the X direction.
If calibration has been performed, the new position value and the previous previous value will be
shown in brackets.
Y: Shows the calibration value in the Y direction.
If calibration has been performed, the new position value and the previous previous value will be
shown in brackets.
Calibrate The fiducial position currently saved is approached and the fiducial is shown in a new
menu on the screen. The fiducial position can be calibrated in this menu.
Approach: The fiducial position currently saved is approached and the fiducial is shown in a new
menu on the screen.
Menu field: Refill position
Check position: The tower is moved to the refill position. You can now check whether all waffle pack
tray carriers can be easily removed.
While the tower is in the refill position, a menu will be shown in which the refill position can be
terminated.

SITEST for WPC4
SITEST Functions Approach
74 Service Manual SIPLACE WPC4
Menu field: Firmware
Version info...: Opens a dialog box containing information about the current firmware version for the
WPC.
This information can be saved as an XML file. (XML = Extended Markup Language)
Menu field: Functions
Reference run: Performs a reference run with the feed and lifting axes.
Transport position: Moves the WPC to a defined position, from which it can be safely transported.
Change WPTC...: Shows the changing time for a waffle pack tray carrier (WPTC) in a certain level.
The level in which the WPTC is can be selected in a dialog box, after which you can start the WPTC
changeover to the staging position. The changeover time actually needed is shown as the result.
Production data..: Opens a dialog box in which the number of level changes up until now and the
production hours are shown.
Continuous run...: Tests the changing of waffle pack tray carriers in a continuous run.
In a separate dialog box, you can set the order and mode for the continuous run and can then start
the continuous run.
Display configuration...: Opens a dialog box containing an overview of which levels in the tower
are set up with a waffle pack tray carrier and which not.
5.6.1 Approach
The fiducial position currently saved is approached and the fiducial is shown on the screen.