WPC4 services manual.pdf - 第85页

SITEST for WPC4 Lifting Axis Positions SITEST Axes Service Manual SIPLACE WPC4 85 5.7.4 Lif ting Axis Positions  Zero point correct ion [µm]: Shows the reference point for calibration of the zero point.  Refill positio…

100%1 / 102
SITEST for WPC4
SITEST Axes Feed Axis Positions
84 Service Manual SIPLACE WPC4
Cancel: Terminates the continuous run.
5.7.3 Feed Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Transfer position [µm]: Shows the feed axis transfer position.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the parameter which you want to change.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
SITEST for WPC4
Lifting Axis Positions SITEST Axes
Service Manual SIPLACE WPC4
85
5.7.4 Lifting Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Refill position [µm]: Shows the position of the lifting axis in which the waffle pack tray carrier can
be removed.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the line with the parameters which you want to edit.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
SITEST for WPC4
SITEST Axes Standard Values
86 Service Manual SIPLACE WPC4
5.7.5 Standard Values
Default speed [0.01 m/s]: Shows the maximum speed of the selected axis.
Default acceleration [0.1 m/s²]: Shows the maximum acceleration with which the feed axis moves
out of the tower.
Default removal speed [0.01 m/s]:Shows the maximum acceleration with which the feed axis
moves into the tower.
OK : Closes the dialog box.
5.7.6 Positioning Data
Speed [0.01 m/s]: Shows the current speed of the selected axis.
Acceleration [0.1 m/s²]: Shows the current acceleration of the selected axis.
Accept: Confirms the entry and closes the dialog box.
NOTE:
The following parameters are for information purposes only and can not be edited.