WPC4 services manual.pdf - 第80页

SITEST for WPC4 SITEST Functions Display Configuration 80 Service Manual SIPLACE WPC4 5.6.6 Display Configuration  Level: Shows the le vel numbers. To the left of each number , an icon shows whether the level contains a…

100%1 / 102
SITEST for WPC4
Continuous Run SITEST Functions
Service Manual SIPLACE WPC4
79
Edit...: Opens a dialog box in which you can select the mode in which the continuous run is to be
tested.
Selecting the continuous run mode
Shows the various types of continuous run available for selection:
Random: The WPC checks which waffle pack tray carriers are present and changes these in a
random order.
Sequence: The WPC checks which waffle pack tray carriers are present and changes these in
sequence.
Switch between level A/B: The WPC changes the waffle pack tray carriers alternatively from "Level
A" and "Level B" until the end of the continuous run.
"Level A" and "Level B" are assigned in the menu
Continuous run
.
X Mark the mode required for the continuous run in the selection list provided.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
SITEST for WPC4
SITEST Functions Display Configuration
80 Service Manual SIPLACE WPC4
5.6.6 Display Configuration
Level: Shows the level numbers.
To the left of each number, an icon shows whether the level contains a waffle pack tray carrier or not.
Green rectangle = level occupied
Empty rectangle = level not occupied
Info: Shows whether a waffle pack tray carrier is present in this level or not.
OK : Closes the dialog box.
SITEST for WPC4
Display Configuration SITEST Axes
Service Manual SIPLACE WPC4
81
5.7 SITEST Axes
Menu field: Axis
This where you can select the WPC axis to be checked or set.
Feed axis: Performs the selected functions for the feed axis.
Lifting axis: Performs the selected functions for the lifting axis.
Menu field: Functions
Reference run: Performs a reference run for the activated axis. The axis concerned remains in the
reference position.
Positioning...: Opens a dialog box in which you can set the target position for the selected axis and
then move the axis to this position.
Control on/off:
Off: Releases the selected axis. This means that the servo board is switched off via the software.
The relevant axis can now be moved mechanically.
On: Activates axis control for the selected axis. The axis is electrically controlled via the control
system and is kept in its position.
Continuous run..: Opens a dialog box in which the start and target positions and the waiting time
can be set for the continuous run and in which the continuous run can then be started.
Menu field: Info
Current position: Shows the current position of the activated axis in mm.
Update position: Updates the position shown for the activated axis.