SITEST for WPC4 SITEST Axes Feed Axis Positions 84 Service Manual SIPLACE WPC4 Cancel: Terminates the continuous ru n. 5.7.3 Feed Axis Positions Zero point correction [µm]: Shows the reference poin t for calibration …

SITEST for WPC4
Continuous Run SITEST Axes
Service Manual SIPLACE WPC4
83
5.7.2 Continuous Run
Start position [µm]: Shows the start position for the selected axis.
Target position [µm]: Shows the target position for the selected axis.
Waiting time [ms]: Shows the time which the selected axis should wait in the start or target position
during the continuous run.
Start: Moves the axis in a continuous run between the specified start and target positions.
Cancel: Closes the dialog box without saving any changes made.
Edit...: Opens a dialog box in which the relevant value can be entered for the level.
Setting values
X Mark the line with the parameters which you want to set.
X Select
Edit …
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.
Starting a continuous run
X Select
Start
.
A dialog box shows the date and time at which the continuous run was started. The continuous run
continues until
Cancel
is selected.

SITEST for WPC4
SITEST Axes Feed Axis Positions
84 Service Manual SIPLACE WPC4
Cancel: Terminates the continuous run.
5.7.3 Feed Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Transfer position [µm]: Shows the feed axis transfer position.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the parameter which you want to change.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel
to reject the entry.

SITEST for WPC4
Lifting Axis Positions SITEST Axes
Service Manual SIPLACE WPC4
85
5.7.4 Lifting Axis Positions
Zero point correction [µm]: Shows the reference point for calibration of the zero point.
Refill position [µm]: Shows the position of the lifting axis in which the waffle pack tray carrier can
be removed.
Min. position approached [µm]: Shows the minimum position reached by the axis.
Max. position approached [µm]: Shows the maximum position reached by the axis.
Accept: Confirms the entry and closes the dialog box.
Cancel: Closes the dialog box and rejects any changes made.
Edit...: Opens a dialog box in which a value can be entered for the parameter in the selected line.
If you want to alter a position, proceed as follows:
X Mark the line with the parameters which you want to edit.
X Select
Edit...
.
X Enter the required value in the input field. Make sure the value entered is within the permissible limits.
X Select
Accept
to confirm your entry or
Cancel