FK-9F98-34 XP T ype II Series T raining T ext for Service Engineers Edition 2.0 XP142E – Chapter 7 Operation and Accuracy Page 5 of 8 7.3 Reverse P AM Side 1 1. Equipment: glass board (Z9731DNPJ002*), reverse measurement…

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 7 Operation and Accuracy Page 4 of 8
12. When measurement is completed press [OK] and select [Results] to display the results of
the measurement. The following window displays:
13. Select [Offset] – [OK] to save the placement offset.
14. Repeat steps 7 to 13 until the results are within the following tolerance:
Average 3∑
X
+/- 0.010 0.030
Y
+/- 0.010 0.030
Q
+/- 0.200 0.200
Side 2
1. Repeat for the side 2 camera, (select side 2 at step 10) and move the parts to the rear
half of the pickup jig as indicated in the photo below:
Glass parts are picked
up from the rear half o
f
the pick up jig
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
7 – 4 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 7 Operation and Accuracy Page 5 of 8
7.3 Reverse PAM
Side 1
1. Equipment: glass board (Z9731DNPJ002*), reverse measurement holder, additional light
source for fiducial camera.
2. Select [Production] – [Select Program] – “ReverseAM-F-192.PGO” – [Download].
3. Set 0.7mm nozzles in all positions on the revolver and in the nozzle editor.
4. Select [Production] – [Nozzle Center Measurement] – [Rotate Center Measurement] –
[START] to carry out a rotate center measurement. Carry this measurement out at least
three times before starting PAM.
5. Select [Production] – [Nozzle Center Measurement] – [Nozzle Center Measurement] –
[START] to carry out a nozzle center measurement. Carry this measurement out at least
three times before starting PAM.
6. Put a feeder loaded with 1005R components in slot 25 of the MFU.
7. Select [Maintenance A] – [Operation Settings] and make the following settings:
Operation Mode Production
Production Mode Automatic
Error handling Error Pass
Accel. Rate 1.00
8. Put double sided tape on the center of the glass board as shown in the photo below:
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
7 – 5 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 7 Operation and Accuracy Page 6 of 8
9. Load the board in the conveyor and select [Production] – [Automatic] – [START] and
placement proceeds.
10. Once placement is completed press [CYCLE STOP] – [Close].
11. Remove the board from the conveyor and place it in the reverse measurement holder.
The surface upon which the components were placed should be facing down:
Insert in conveyor
in this direction
(Left to Right
conveyor). Plastic
stopper is at the
right of the holder.
12. Change the conveyor width to 198.5mm.
13. Install the additional light source on the fiducial camera as indicated in the photo below:
Install the light source
Connect this cable
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
7 – 6 CS Section