np134 mechanical reference-1.1e.pdf.pdf - 第55页

8. Slowly pull the PFU-4E/5E away from the machine. NP1MS063 Guide rails Part 2 Chapter 4 Detaching a PFU-4E/5E Edition 1.0 2-4-2 NP-134E/134ME Mechanical

100%1 / 110
4. Detaching a PFU-4E/5E
Procedure
1. Use the positioning commands or the inching keys at the machine to move the
placing head to its retract position.
CAUTION
The placing head can be damaged if this procedure is not
carried out correctly.
2. At the [Main] window, press [Unit]
3. Select [Stage1] or [Stage2] then press [Power Off].
CAUTION
The power supply board may be damaged if this procedure
is not carried out correctly.
4. At the rear of the PFU-4E/5E, open the jack box.
5. Remove the parts of the jack lever and join them.
6. Attach the lever to the valve of the jack and turn it clockwise to close the valve.
7. Using the lever, jack the PFU-4E/5E up until the marker comes to the tip of the
indicator.
Marker
Indicator
Valve
NP1MS060
Jack door
Jack lever
NP1MS059
Part 2 Chapter 4 Detaching a PFU-4E/5E
Edition 1.0 2-4-1 NP-134E/134ME Mechanical
8. Slowly pull the PFU-4E/5E away from the machine.
NP1MS063
Guide rails
Part 2 Chapter 4 Detaching a PFU-4E/5E
Edition 1.0 2-4-2 NP-134E/134ME Mechanical
Part 3
Maintenance