np134 mechanical reference-1.1e.pdf.pdf - 第70页

Notes: Part 3 Chapter 1 Cleaning Edition 1.0 3-1-14 NP-134E/134ME Mechanical

100%1 / 110
Cleaning Check Points
Cleaning Points
Cleaning the Nozzle
Cleaning the Filter inside the Nozzle Sleeve
Cleaning the Nozzle Fluorescent Seal
Emptying the Reject Parts Box
Cleaning the Parts Camera Prism
Emptying the PFU Waste Tape Box
Cleaning the Filter Regulator
Cleaning the Inside of the Machine
Cleaning the Nozzle Shaft
Cleaning the Y-axis Motor Cooling Fan Filter
Weekly
Weekly
Monthly
Every 8 Hours
Monthly
Every 2 Hours
Monthly
Weekly
Every 1000 Hours
Monthly
Cleaning Schedule
Table-020a
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
Check
Part 3 Chapter 1 Cleaning
Edition 1.0 3-1-13 NP-134E/134ME Mechanical
Notes:
Part 3 Chapter 1 Cleaning
Edition 1.0 3-1-14 NP-134E/134ME Mechanical
2. Lubrication
Precautions During Lubrication
1) Prior to beginning any lubrication, turn the main breaker off.
2) Apply an appropriate amount of lubricant. If too much lubricant is applied, it
may splatter and drop on panels inside the machine. Special care should be taken
to keep the camera lens clean, as a soiled lens results in poor part inspection
results. Use a lens cleaner to keep the lens clean.
Types of Lubricant
The lubricants which are used have the following characteristics.
Type
Characteristics
Table-lub-NP1Ea
Lithium grease by Idemitsu suited to mid/low parts.
Daphne Eponex No. 2
EVERS-2
Anti-corrosive oil with high lubrication and penetrating
charachteristics.
Biral T&D
Anticorrosive spray on oil suited to low speed, low load
parts.
Part 3 Chapter 2 Lubrication
Edition 1.1 3-2-1 NP-134E/134ME Mechanical