Error Code List.pdf - 第24页

AV131 ERROR CODE LIST 2.4 Errors D79EEC- 91-210-A 0 2.4- 1 2.4. Errors D79EEC - 91-210-A 0 7 E m ergency sw itch ON DESCRI PTIO N E m ergency sw itch wa s de t e ct ed. CAUSE An e mergency s top sw itch was pre ssed. SOL…

100%1 / 76
AV131
ERROR CODE LIST
2.3 Error Code Table
D79EEC-91-030-A0
2.3-6
Error code Message
9294
Soft task comm. Error
9295
Soft calculation error
9304
Motion incomplete
9305
Soft parameter error
9308
Soft overrun limit
9369
Exclusion process error
9372
Position interrupt error
9373
Complete interrupt error
9400
Axis error
9801
Auto width power on error
9802
Auto width origin return incomplete
9803
Auto width positioning incomplete
9804
Auto width emergency stop input
9805
Auto width command error
9806
Auto width parameter error
9807
Auto width communication error
9809
Auto width origin abnormal
9812
Auto width + overrun error
9813
Auto width - over run error
AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-1
2.4. Errors
D79EEC-91-210-A0
7
Emergency switch ON
DESCRIPTION
Emergency switch was detected.
CAUSE
An emergency stop switch was pressed.
SOLUTION
Release the emergency stop switch. (There are five switches. Front; 2 Rear; 3) If the same message appears after
releasing the switch, the switch may be broken. Confirm emergency SW signal in the [Input check] of [Machine
adjustment].
NOTE
8
Servo switch OFF
DESCRIPTION
Servo switch off
CAUSE
A servo switch is pressed.
SOLUTION
Release the servo switch (1 in front and 1 in back). (KEYLOCK LED of operation panel turns OFF.)
If the same message appears after releasing the switch, the switch may be broken.
NOTE
9
Air pressure drop
DESCRIPTION
Air pressure drop
CAUSE
Air pressure has dropped.
SOLUTION
When supplied air pressure has dropped, supply air at 0.49MPa - 0.78MPa.
Excessively high setting of the air pressure detector causes an error. Set to 0.4MPa.
Confirm Air pressure (5800H:bit2) in the [input check] of [machine adjustment]. ON: OK, OFF: Drop
NOTE
12
Cover open stop
DESCRIPTION
Door or cover is open
CAUSE
Safety cover is left open.
SOLUTION
Close the door or cover, then push [return].
Confirm Cover switch (5800H:bit3, 4, 5) in the [input check] of [machine adjustment]. ON: Close, OFF: Open
NOTE
17
PCB transport error
DESCRIPTION
PCB remains at the transferring part, or PCB is broken.
CAUSE
PCB cannot be transferred properly.
SOLUTION
Check the PCB transfer unit for proper operation.
NOTE
AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-2
20
Illegal setting of width of PCB
DESCRIPTION
An obstacle was detected during the width adjustment of the conveyors.
CAUSE
The width of the PCB on the PCB data can be wrong or the holder position can be set in excess of PCB width.
SOLUTION
If a holder is outside the PCB dimension in the conveyor Y direction, move the pin to its correct position.
Check that the support pin detection sensor (PH530, PH531) turns on or off properly.
If obstacles exist, remove them.
NOTE
34
Counter error
DESCRIPTION
Counter error of axis controller
CAUSE
Trouble of axis controller board in CPU box
SOLUTION
Necessary to exchange axis controller board.
Please inform us the axis name and the situation.
NOTE
35
Returning to origin error
DESCRIPTION
Incomplete returning to origin
CAUSE
Axis can't move smoothly.
Motor driver trouble
Trouble of axis controller board in CPU box
Getting loose of motor coupling
Disconnection of motor wiring
Trouble of axis I/O sensor
SOLUTION
Inspection of axis. (Dust etc.)
Exchange motor driver.
Exchange axis controller board.
Confirm I/O sensor status in the [Input check] of [Machine adjustment]. Check 1260H, 1261H, 1262H, 1263H, 9806H,
9816H, 9826H, A006H, A016H, A026H, A806H, A816H, A826H, A836H, B006H, B016H, B026H, B036H.
Please inform us the axis name and the situation.
NOTE
37
Data error (Soft limit)
DESCRIPTION
Move data beyond limit is sent to axis controller.
CAUSE
Move data beyond limit exists in pickup position data and mount data.
SOLUTION
Check pickup position data and mount data.
Please inform us the axis name and the situation.
NOTE
38
(+) Overrun
DESCRIPTION
Axis (+) overrun sensor is ON.
CAUSE
Trouble of sensor
SOLUTION
Execute return to origin in the [Ret orig] of [Machine adjustment].
[Confirm I/O sensor status in the [Input check] of [Machine adjustment].
Confirm setting of CPU box board (MCMJEX) and connection of connector.
Please inform us the axis name and the situation.
NOTE