Error Code List.pdf - 第30页
AV131 ERROR CODE LIST 2.4 Errors D79EEC- 91-210-A 0 2.4- 7 1700 XY inte rlo ck (R igh t rail ) DESCRI PTIO N Int er lock was detecte d betwe en XY t able and right r ail. CAUSE W hi l e X Y tab l e i s moving right ra il…

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-6
1306
Data check
DESCRIPTION
Data do not meet the creating condition. Data do not satisfy the production condition.
CAUSE
Data condition required for production is insufficient.
SOLUTION
Enter the Data modification mode and press the data check key to confirm NG data items. And then change data.
NOTE
1307
Thermal trip (Blower)
DESCRIPTION
Thermal switch for the blower has detected overcurrent.
CAUSE
Tripped thermal switch for the blower.
SOLUTION
Reset the thermal relay.
NOTE
1310
Driver condition
DESCRIPTION
Trouble is found in the servo driver.
CAUSE
Servo driver alarm signal was detected.
SOLUTION
Cancel the driver error.
NOTE
1314
Safety relay
DESCRIPTION
Safety relay has not been properly reset.
CAUSE
There are some troubles in the safety relay.
SOLUTION
Replace the safety relay.
NOTE
1316
Thermal trip (Pump)
DESCRIPTION
Thermal switch for the Pump has detected overcurrent.
CAUSE
Thermal switch for the Pump was activated due to overcurrent.
SOLUTION
Reset the thermal relay.
NOTE
1516
Driver communication error
DESCRIPTION
Communication with an axial driver went wrong.
CAUSE
Communication error between the NC board and driver was detected.
SOLUTION
Call the Servicing Department of our company.
NOTE

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-7
1700
XY interlock (Right rail)
DESCRIPTION
Interlock was detected between XY table and right rail.
CAUSE
While XY table is moving right rail traverse limit sensor (80000:bit0) was detected.
SOLUTION
Please confirm whether right rail is down position. Please confirm right rail traverse limit sensor.
NOTE
1701
XY interlock (Left rail)
DESCRIPTION
Interlock was detected between XY table and left rail.
CAUSE
While XY table is moving left rail traverse limit sensor (80040:bit4) was detected.
SOLUTION
Please confirm whether left rail is down position. Please confirm left rail traverse limit sensor.
NOTE
1702
Auto width interlock
DESCRIPTION
Auto width interlock was detected.
CAUSE
Interlock signal was input while auto width running.
It tried to operate auto width axis with the interlock signal input.
SOLUTION
Please confirm interlock signal. Interlock signal to which the auto width refers is as follows.
<Interlock signal> PCB detection 1 (80000:bit2) PCB detection 2 (80000:bit3) PCB detection 3 (80040:bit6) PCB
detection 4 (80040:bit7) XY table PCB detection (80003:bit0)
Right belt motor output (Positive rotation 80020:bit2) (Reverse rotation 80020:bit3)
Left belt motor output (Positive rotation 80060:bit2) (Reverse rotation 80060:bit3)
Safety cover (80581:bit0/bit1/bit2/bit3) Emergency input (80581:bit4/bit5/bit6/bit7)
XY axis origin (NC origin) H axis origin (M.ORG)
NOTE
1703
Air down interlock
DESCRIPTION
Air pressure was down.
CAUSE
Air down sensor (80002:bit5) was detected while machine was running.
SOLUTION
Please confirm whether the air pressure is correct.
NOTE
1704
Brake switch interlock
DESCRIPTION
H axis brake switch became a release side.
CAUSE
Brake SW input (80081:bit5) was release side while H axis was running.
SOLUTION
Please switch the brake switch to a lock side.
NOTE

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-8
1705
Handle interlock
DESCRIPTION
Pushing H axis rotation wheel was detected.
CAUSE
H axis wheel detection (800C3:bit2) was detected while H axis was running.
SOLUTION
Please return H axis rotation wheel to original position.
NOTE
1706
Feeder float interlock (Left)
DESCRIPTION
Feeder float interlock of left part supply unit was detected.
CAUSE
ZL feeder float detection sensor (80041:bit1) was detected while ZL axis was running.
SOLUTION
Please confirm the setting of part supply unit left feeder.
NOTE
1707
Feeder float interlock (Right)
DESCRIPTION
Feeder float interlock of right part supply unit was detected.
CAUSE
ZR feeder float detection sensor (80001:bit6) was detected while ZR axis was running.
SOLUTION
Please confirm the setting of part supply unit right feeder.
NOTE
1708
Power failure interlock
DESCRIPTION
The power failure was detected while the machine was running.
CAUSE
Power failure (80580:bit7) was detected while the machine was running.
SOLUTION
Please turn power failure reset signal (805A0:bit7) on and off by the [Output check] of [Machine adjustment] to reset
power failure.
NOTE
1709
θH axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the θH axis was detected.
CAUSE
θH plus overrun (800C1:bit2) was detected while the θH axis was running. θH axis is located near mechanical
stopper.
SOLUTION
Please confirm θH plus overrun detection. Please confirm θH axis position.
NOTE
1710
θA axis plus overrun interlock
DESCRIPTION
The plus overrun interlock of the θA axis was detected.
CAUSE
θA plus overrun (80041:bit4) was detected while the θA axis was running. θA axis is located near mechanical
stopper.
SOLUTION
Please confirm θA plus overrun detection. Please confirm θA axis position.
NOTE