Error Code List.pdf - 第73页
AV131 ERROR CODE LIST 2.4 Errors D79EEC- 91-210-A 0 2.4- 50

AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-49
9807
Auto width communication error
DESCRIPTION
The communication fault with the pulse control board.
CAUSE
The communication checksum data from pulse control board is not correct.
SOLUTION
The operation situation is confirmed. Please contact our service section.
NOTE
9809
Auto width origin abnormal
DESCRIPTION
Auto width origin return was not normally completed.
CAUSE
Return-to-origin was not complete within the specified period of time.
Breakdown of origin return sensor.
SOLUTION
Please confirm whether auto width axis moves smoothly.
Please confirm whether the origin sensor correctly detects it.
NOTE
9812
Auto width + overrun error
DESCRIPTION
+ Overrun sensor for the auto width axis was activated.
CAUSE
The + overrun sensor was shaded during the movement in a positive direction.
SOLUTION
Check how the overrun sensor is attached and worked.
NOTE
9813
Auto width - over run error
DESCRIPTION
- Overrun sensor for the auto width axis was activated.
CAUSE
The - overrun sensor was shaded during the movement in a negative direction.
SOLUTION
Check how the overrun sensor is attached and worked.
NOTE