Error Code List.pdf - 第64页

AV131 ERROR CODE LIST 2.4 Errors D79EEC- 91-210-A 0 2.4- 41 2682 26 / 52 change error DESCRI PTIO N The re sult of 26 mm c huck shu nting de tection se nsor i n s li de chuck w as not co rrespond i ng to chuck infor mati…

100%1 / 76
AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-40
2673
Anvil short error (left & right lead detection)
DESCRIPTION
Insertion of both leads was detected during trial where no part is supposed to be inserted.
CAUSE
Improper adjustment of clincher blade position
Dirt adhered to the inside of the clincher.
Clogged suction hose of the anvil
Contact failure in the wiring to the insertion detection box
Anvil is within the dead space at the insertion position.
Another part inserted to a position where a part has already been inserted.
SOLUTION
Readjust the clincher.
Remove the clincher and clinch base, then clean inside.
Clear the clogged hose. Dispose of any accumulated wastes inside the waste bottle.
Check for wire break and contact of the connectors.
Check the dead space.
Check the insertion position.
NOTE
2674
Anvil short error (left lead detection)
DESCRIPTION
Insertion of left lead was detected during trial where no part is supposed to be inserted.
CAUSE
Improper adjustment of clincher blade position
Dirt adhered to the inside of the clincher.
Clogged suction hose of the anvil
Contact failure in the wiring to the insertion detection box
Anvil is within the dead space at the insertion position.
Another part inserted to a position where a part has already been inserted.
SOLUTION
Readjust the clincher.
Remove the clincher and clinch base, then clean inside.
Clear the clogged hose. Dispose of any accumulated wastes inside the waste bottle.
Check for wire break and contact of the connectors.
Check the dead space.
Check the insertion position.
NOTE
2675
Anvil short error (right lead detection)
DESCRIPTION
Insertion of right lead was detected during trial where no part is supposed to be inserted.
CAUSE
Improper adjustment of clincher blade position
Dirt adhered to the inside of the clincher.
Clogged suction hose of the anvil
Contact failure in the wiring to the insertion detection box
Anvil is within the dead space at the insertion position.
Another part inserted to a position where a part has already been inserted.
SOLUTION
Readjust the clincher.
Remove the clincher and clinch base, then clean inside.
Clean the clogged hose. Dispose of any accumulated wastes inside the waste bottle.
Check for wire break and contact of the connectors.
Check the dead space.
Check the insertion position.
NOTE
AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-41
2682
26 / 52 change error
DESCRIPTION
The result of 26 mm chuck shunting detection sensor in slide chuck was not corresponding to chuck information on
the insertion parts.
CAUSE
26/52 pitch switch action may not be completed up to the cycle timer 280 degrees.
There is a possibility of the breakdown of 26 mm shunting detection sensor.
SOLUTION
Please confirm whether 26 / 52 pitch switch operates correctly.
Please confirm whether 26 mm shunting sensor detect correctly.
NOTE
2696
No PCB on XY table
DESCRIPTION
XY table failed to detect PCB.
CAUSE
Reference pin has not been positioned to the reference hole of the PCB correctly.
Faulty PCB detection sensor
Bent PCB detection lever
SOLUTION
Check if the PCB is positioned properly to the XY table.
Check that the PCB detection sensor functions properly.
Check the PCB detection lever for any bent.
NOTE
2697
Feeder type error (26 / 52)
DESCRIPTION
Feeder (loaded on the part supply unit) type error was detected.
CAUSE
Feeder type specified in the parts data and actual feeder do not agree.
(1) The type of the feeder loaded on the part supply unit is wrong.
(2) The type of the feeder in the parts data has not been specified correctly.
SOLUTION
Check the feeder type loaded on the part supply unit.
Check the feeder type specified in the parts data.
NOTE
2707
H axis origin off
DESCRIPTION
H axis has not stopped in the machine origin.
CAUSE
H axis has come off from the machine origin.
SOLUTION
Please make H axis servo free and return H axis to the machine origin by the handle operation.
NOTE
2708
Feeder float detection error
DESCRIPTION
Feeder float of part supply unit was detected.
CAUSE
Before moving part supply axis feeder float detection sensor was detected.
SOLUTION
Please confirm the setting of feeder on part supply unit.
NOTE
AV131
ERROR CODE LIST
2.4 Errors
D79EEC-91-210-A0
2.4-42
2710
Safety relay reset condition
DESCRIPTION
Safety relay is still open when operate safety stop clear. So safety stop condition is still continued.
CAUSE
Safety relay may be abnormal. There is a possibility that some cover still opened.
SOLUTION
Please confirm safety relay by the input check of the machine adjustment.
Please confirm whether all the covers are closed.
NOTE
2731
PCB carry in restart cancel
DESCRIPTION
Restart of PCB carry-in was canceled.
CAUSE
Conditions required for restarting PCB carry-in may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB carry-in.
NOTE
2732
PCB carry out restart cancel
DESCRIPTION
Restart of PCB carry-out was canceled.
CAUSE
Conditions required for restarting PCB carry-out may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB carry-out.
NOTE
2733
PCB sweep out restart cancel
DESCRIPTION
Restart of PCB sweep-out was canceled.
CAUSE
Conditions required for restarting PCB sweep-out may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB sweep-out.
NOTE
2734
PCB carry start conditional not satisfies
DESCRIPTION
Failed to start PCB carry.
CAUSE
Lack of conditions required for starting PCB carry
SOLUTION
Check the conditions for starting PCB carry.
NOTE
2735
Rail down condition not satisfies
DESCRIPTION
The rail failed to be moved down.
CAUSE
Lack of conditions required for moving down the rail.
SOLUTION
Check the conditions for moving down the rail.
NOTE