SYS-CP842-1.1E.pdf - 第32页
SYS-CP842-1.1E 2.The Machine CP-842E / CP-842ME System Reference 23 Note: This explanation describes single pa nel production. The double panel production option is th e same except for th e use of stop pe rs to position…

2.The Machine SYS-CP842-1.1E
22 CP-842E / CP-842ME System Reference
11. Panel unclamping and unloading
When population of the current panel(s) is complete, the XY-table moves to the out-carrier.
At this position, the XY-table is raised and the panel is transferred from the table to the out-
carrier (K).
The out-carrier subsequently moves to the out-conveyor and the panel is lowered onto the
out-conveyor via the out-lifter. The panel is unloaded (L).
J
XY-table
Placing head
ST1
ST2
ST3
ST4
ST5
ST6
ST7
ST8
ST9
ST13
ST16
ST15
ST14
ST12
ST11
ST10
K
Out-carrier

SYS-CP842-1.1E 2.The Machine
CP-842E / CP-842ME System Reference 23
Note: This explanation describes single panel production. The double panel production
option is the same except for the use of stoppers to position the second panel at the in- and
out-conveyor.
L
Out-conveyor
C7SM1003a

2.The Machine SYS-CP842-1.1E
24 CP-842E / CP-842ME System Reference
2.1.4 Machine Controls
The machine uses a combination of a touch screen and conventional push buttons.
The major buttons on the operation box and touch screen are detailed below.
POWER ON lamp
This indicator is lit when the main breaker is set to the ON position.
SYSTEM ON button
This button turns on the power supply to the machine and boots up the control software.
START button
This button is pushed to commence operation. This button can only be pushed when the
machine is in START ready status (i.e., when the button is flashing).
POWER
ON
READY
ON
Side 1
START
EMERGENCY
STOP
SYSTEM
ON
ENABLE
LOCK
CYCLE
STOP
F
θ
θ