1 17 SOM-2080 6.1 1 Others 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 4b0307 Feeder Base The connector (rear side) for the feeder base worked off. Do not remove the connector during feeder base ascent.[…

100%1 / 179
116
SOM-2080
6.11 Others
1005-001
6.11 Others
Table 13
Erroe ID Error Name, Description, Cause, and Remedy
4b0101 Head Mis-Pick-up Detection
Auto Run can't be performed with the Mis-Pick-up Component on the head.
Please perform abandonment operation from a control menu.
4b0201 Feeder communication Error.
Communication with the feeder has error.
Please check the number of component remain.
4b0202 Feeder communication Error.
Communication with the feeder has error.(System error)
-----
4b0203 Feeder communication Error.
Feeder Alarm. Please confirm the feeder and the component.
-----
4b0204 Feeder communication Error.
Communication with feeder was not completed within predetermined time.
(Please take out and insert feeder.)
-----
4b0205 Feeder communication Error.
Failed in reading feeder data. (There is a chance of failure in feed pitch writing.)
Remove and insert feeder back in.
4b0301 Feeder Base
The feeder base detection was interrupted while the cutter was working.
[B0910,B0911]
-----
4b0302 Feeder Base
The feeder unclamp operation was not completed within predetermined time.
-----
4b0303 Feeder Base
Feeder operation errors
Please check after removing feeder in the case of using tape feeder. Please
check part of component supply in the case of using tray.
4b0304 Feeder Base
The feeder clamp operation was not completed within predetermined time.
-----
4b0305 Feeder Base
The feeder base ascent operation was not completed within predetermined time.
Check the feeder base upper limit position.
4b0306 Feeder Base
The feeder base descent operation was not completed within predetermined time.
Check the feeder base lower limit position.
117
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b0307 Feeder Base
The connector (rear side) for the feeder base worked off. Do not remove the
connector during feeder base ascent.[B0916]
Connect the connector (rear) for the feeder base to the machine main body.
4b0308 Feeder Base
The connector (front side) for the feeder base worked off. Do not remove the
connector during feeder base ascent.[B0916]
Connect the connector (front) for the feeder base to the machine main body.
4b0309 Feeder Base
The check 1 of the feeder base locating in (rear) Y-direction is impossible.[B0910]
Set the feeder base to the machine.
4b030a Feeder Base
The check 2 of the feeder base locating in (rear) Y-direction is impossible.[B0911]
Set the feeder base to the machine.
4b030b Feeder Base
The check 1 of the feeder base locating in (front) Y-direction is impossible.[B0910]
Set the feeder base to the machine.
4b030c Feeder Base
The check 2 of the feeder base locating in (front) Y-direction is impossible.[B0911]
Set the feeder base to the machine.
4b0401 Recycling Conveyor
The recycle conveyer (back) was filled up. [B0924]
Please push a manual switch, and remove parts on the recycling conveyer.
4b0402 Recycling Conveyor
The recycle conveyer (front) was filled up. [B0924]
Please push a manual switch, and remove parts on the recycling conveyer.
4b0403 Recycling Conveyor
The recycling conveyer (back) motor operation time out.
There is a possibility a problem in the motor wiring. Please check the motor
wiring. Please begin the production.
4b0404 Recycling Conveyor
The recycling conveyor (front) motor operation time out.
There is a possibility a problem in the motor wiring. Please check the motor
wiring. Please begin the production.
4b0405 Recycling Conveyor
The component trash box (back) was filled up. [B0925]
Open the safety door, and clean out the wastages in it.
4b0406 Recycling Conveyor
The component trash box (front) was filled up. [B0925]
Open the safety door, and clean out the wastages in it.
4b0501 Manual Opn Error
Operation was not completed within predetermined time.
-----
118
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b050f Manual Opn Error
Error was detected during operation.
-----
4b0601 Auto Run Start Error
Production operation has not started within predetermined time. (Please push a
start button again)
-----
4b0701 Communication Timeout
Communication failed to STG.#1 CPU
-----
4b0702 Communication Timeout
Communication failed to STG.#2 CPU
-----
4b0703 Communication Timeout
Communication failed to Recog CPU
-----
4b0704 Communication Timeout
Communication failed to STG CPU
-----
4b0705 Communication Timeout
The data could not be received in time.
-----
4b0706 Communication Timeout
Since the data could not be received in time, the pitch of the feeder was not
turned back.
Perform the feeder ready OFF and then, ON to return the feeder pitch.
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
-----
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
-----
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
-----
4b0901 Firmware Updating Timeout
Firmware update did not end in prescribed time.
-----
4b0a01 Feeder Alarm
Feeder Alarm. Please confirm the feeder and the component.
-----
4b0b01 Feeder base-main body connector unconnection
The connector on the feeder base-main body was disconnected. [B0916]
Please connect the connector on the feeder base to the main body, and press the
stage leady SW.