SOM-2080-001_w.pdf - 第169页

166 SOM-2080 Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 801401 Data Check Pick-up Level Data(Calculated data) is out of range. Please check l…

100%1 / 179
165
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
800F06 Program Change Warning
800F07 Program Change Warning
800F81 Program Change Warning
800F82 Program Change Warning
800F83 Program Change Warning
800F84 Program Change Warning
801001 Auto Offset Teach Information
Tape pocket recog error(run continue)
801101 Nozzle diameter confirmation
The disagreement of the nozzle diameter was detected with the linear measure.
There is a possibility of the linear measure dirt and the nozzle dirt,please confirm
whether a different nozzle has adhered.
801201 Stat Auto Head Recovery
Cpu Communication error occurred.(CPU2-CPU3)
801202 Stat Auto Head Recovery
Head cam origin return action not complete.(Not CAM ORIGIN position)
801203 Stat Auto Head Recovery
Head Driver communication is time out.(from cpu3 job)
801204 Stat Auto Head Recovery
Nozzle change action not complete.(cam lock action NG)
801205 Stat Auto Head Recovery
Head cam position return action not complete.
801206 Stat Auto Head Recovery
Nozzle change action not complete.(cam free action NG)
801207 Stat Auto Head Recovery
Nozzle change action not complete.(Not CAM ORIGIN position)
801208 Stat Auto Head Recovery
Unselected Nozzle Drop.
801209 Stat Auto Head Recovery
Component output error(Pick-up error) is detected by nozzle level was position.
;Nozzle posture detection
80120a Stat Auto Head Recovery
The selected nozzle was not at position. ;Nozzle posture detection
80120b Stat Auto Head Recovery
Component output error(Others) is detected by nozzle level was position. ;Nozzle
posture detection
801301 Pick-up Position Feedback
Feedback value out of range. Please check feeder.
6.19 Machine Information
1005-001
166
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801401 Data Check
Pick-up Level Data(Calculated data) is out of range. Please check library data
and offset data.
801402 Data Check
Placement height Data(Calculated data) is out of range. Please check library data
and offset data.
801403 Data Check
The data out of the setting range is contained in the feeder offset B data of
system data. On edit screen, X/Y of the components (tape width 8mm / sending
pitch 2mm) should be set as more than -1.0mm and less than +1.0mm.
801404 Data Check
The data out of the setting range is contained in the placement level data of
component supply changed data. On edit screen, the place level of square shape
below 3216 should be set up less than +0.5mm. When the place level exceeding
0.5mm is required, please input H data of placement data (PP data).
801405 Data Check
Data other than 0 are input to H offset of the pattern program data (height data).
There is a possibility of the component damage when the component is placed.
Please confirm whether the input data is correct.
801501 Feeder Index Position
Production operation was interrupted in the middle of feeder index operation.
Please check a position.
801502 Feeder Index Position
The feeder carriage was returned to the home position in the middle of feeder
index operation. Please check a feeder index position.
801601 Product Restart
Restart production with semi-auto(after specified step) mode.
801602 Product Restart
Restart production with warm start mode.
801603 Product Restart
Restart production with warm start mode. Machine will stop after placement
complete. Please confirm PCB afterward.
801701 Teach Nozzle Bypass
Nozzle Down Error.(L)
801702 Teach Nozzle Bypass
Nozzle Down Error.(H)
801703 Teach Nozzle Bypass
Recognition Teach Error.
801704 Teach Nozzle Bypass
Teach Error Data.
801705 Teach Nozzle Bypass
Lighting Check.
801706 Teach Nozzle Bypass
Nozzle Level.
6.19 Machine Information
1005-001
167
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801707 Teach Nozzle Bypass
Nozzle Drop
801708 Teach Nozzle Bypass
Dummy Nozzle.
801709 Teach Nozzle Bypass
Manual Bypass.
80170a Teach Nozzle Bypass
Nozzle Change Error.(Cam lock action)
80170b Teach Nozzle Bypass
Nozzle Change Error.(Cam Free action)
80170c Teach Nozzle Bypass
Cam Origin Error.
80170d Teach Nozzle Bypass
Nozzle Teach Error.
80170e Teach Nozzle Bypass
Nozzle Posture Detection
801801 Teach Head Bypass
Communication Error.
801802 Teach Head Bypass
Head Origin.
801803 Teach Head Bypass
Overtime Head Origin Return.
801804 Teach Head Bypass
Unselected Nozzle Drop.
801805 Teach Head Bypass
Dummy Nozzle.
801806 Teach Head Bypass
Manual Bypass.
801807 Teach Head Bypass
Alarm Error.
801901 Nozzle Adjustment
Nozzle up&down action is not available.
801902 Nozzle Adjustment
Communication error.
801a01 Warning Operation
Product started by RUN MODE "PASS"Operation.
801a02 Warning Operation
The PCB before component placing was conveyed from X/Y table.
801a03 Warning Operation
The PCB in the middle of component placing was conveyed from X/Y table.
801a04 Warning Operation
The feeder ready button was turned on in start protection mode.
801a05 Warning Operation
Cannot alternate by external start protection.
6.19 Machine Information
1005-001