SOM-2080-001_w.pdf - 第145页

142 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 601d01 Library teaching Abnormality was found in the division recognition position movement when the library was taught. Please make a new library instruct…

100%1 / 179
141
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
601a04 Linear measure correction re-teach
The linear measure control has an error.
-----
601a05 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R)
-----
601a06 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/NR)
-----
601a07 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R & E/NR detection error)
-----
601a08 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error:
Shortage of Samples)
-----
601a09 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Failed
in the generation of the correction formula.)
-----
601a0a Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Inside
accuracy check error)
-----
601a0b Linear measure correction re-teach
The measurement value of the nozzle is not within 0.2mm - 0.6mm.
Adjust the height of the linear measure sensor otherwise, replace it.
601a0c Linear measure correction re-teach
The firmware is not applicable to the correcting creation.
Update the version by Ver.008 firmware or later.
601b01 Automatic teaching
The nozzle is not installed.
Please install the nozzle.
601c01 Camera bad mark teaching
There is spots in the bad mark inspection area.
-----
6.14 Automatic Teaching
1005-001
142
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
601d01 Library teaching
Abnormality was found in the division recognition position movement when the
library was taught.
Please make a new library instruction again.
601e01 Board height measurement teach
Recognition mark is abnormal
Please carry out remaining teach after having manual alignment.
601e02 Board height measurement teach
Abnormality occurred during board height measurement teach movement.
-----
601e03 Board height measurement teach
Failed teaching: The measurement is wrong.
Clean the surface of the jig.
601e04 Board height measurement teach
Failed Teaching: The jig is tilting.
Reposition it with the P.C.B. thickness reviewed.
601e05 Board height measurement teach
Failed Teaching: Jig Recognition Error
Check the condition in locating the jig P.C.B.
601f01 NL Axis offset teach
Linear measure was found abnormality while measuring.
-----
601f02 NL Axis offset teach
The result of the linear measure sensor is out of the tolerance.
-----
601f03 NL Axis offset teach
An error for the NS axis movement occurred.
-----
601f04 NL Axis offset teach
Time out of the NS axis movement occurred.
-----
601f05 NL Axis offset teach
An error for the DD axis movement occurred.
-----
601f06 NL Axis offset teach
Time out of the DD axis movement occurred.
-----
601f07 NL Axis offset teach
An error for the NL axis movement occurred.
-----
601f08 NL Axis offset teach
Time out of the NL axis movement occurred.
-----
6.14 Automatic Teaching
1005-001
143
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
601f09 NL Axis offset teach
An error occurred in the teaching operation.
-----
602001 Auto. Teaching Mode in Auto.Opn
A recog error occurred during teaching operation.(Back) (This problem may be
caused by the teaching jig unset or dirty.)
Check that the teaching jig is set properly on the position, or clean the teaching
jig.
602002 Auto. Teaching Mode in Auto.Opn
A recog error occurred during teaching operation.(Front) (This problem may be
caused by the teaching jig unset or dirty.)
Check that the teaching jig is set properly on the position, or clean the teaching
jig.
602003 Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Rear)
-----
602004 Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Front)
-----
602005 Auto. Teaching Mode in Auto.Opn
An error for timeout occurred during teaching. (Rear)
-----
602006 Auto. Teaching Mode in Auto.Opn
An error for timeout occurred during teaching. (Front)
-----
602007 Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Rear) (Operation timeout in the Beam Offset
Teaching)
-----
602008 Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Front) (Operation timeout in the Beam Offset
Teaching)
-----
602009 Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Rear) (Operation error in the Beam Offset
Teaching)
-----
60200a Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Front) (Operation error in the Beam Offset
Teaching)
-----
60200b Auto. Teaching Mode in Auto.Opn
An error occurred during teaching. (Rear) (Operation timeout in the Head Rotation
Center Offset Teaching)
-----
6.14 Automatic Teaching
1005-001