148 SOM-2080 6.16 V .Bend Detection System Error 1005-001 6.16 V .Bend Detection System Error T able 18 Erroe ID Error Name, Description, Cause, and Remedy 6b0101 V.Bend Detection System Error Communication time-out. Che…

147
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
610602 Board height measurement adjustment
Measurement ranges exceed board size.
-----
610603 Board height measurement adjustment
There is the measurement point which exceed the board size.
-----
6.15 Test
1005-001

148
SOM-2080
6.16 V.Bend Detection System Error
1005-001
6.16 V.Bend Detection System Error
Table 18
Erroe ID Error Name, Description, Cause, and Remedy
6b0101 V.Bend Detection System Error
Communication time-out.
Check the coupling network cable between the V-bend unit PC and the main
machine.
6b0102 V.Bend Detection System Error
Error command.
Shut down the machine and power it up again.
6b0103 V.Bend Detection System Error
Error received data.
Shut down the machine and power it up again.
6b1001 V.Bend Detection System Error
Syetem error. (1000)
Shut down the machine and power it up again.
6b1011 V.Bend Detection System Error
Memory error in unit.(1010)
Shut down the machine and power it up again.
6b1061 V.Bend Detection System Error
Laser error.(1060)
Shut down the machine and power it up again.
6b1071 V.Bend Detection System Error
Memory error insensor section. (1070)
Shut down the machine and power it up again.
6b1081 V.Bend Detection System Error
Sensor cable not connected. (1080)
Check the connection between the V-bend unit PC and the sensor head.
6b1091 V.Bend Detection System Error
Unsteady mortor rotaion in sensor. (1090)
Check the connection of the power cable for the sensor head.
6b1101 V.Bend Detection System Error
Laser OFF. (1100)
Shut down the machine and power it up again.
6b2001 V.Bend Detection Operation Error
-----
-----
6b2011 V.Bend Detection Operation Error
Wrong level adjustment. (2010)
Shut down the machine and power it up again.
6b2031 V.Bend Detection Operation Error
Wrong component no. (2030)
Shut down the machine and power it up again.

149
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
6b2041 V.Bend Detection Operation Error
Measurement Start Signal Not Recognized. (2040)
Check the coupling cable between the V-bend unit PC and the main machine.
(Measurement Start Signal)
6b2051 V.Bend Detection Operation Error
Illegal Command Parameter. (2050)
Shut down the machine and power it up again.
6b2061 V.Bend Detection Operation Error
Unknown Reference Component Data. (2060)
Shut down the machine and power it up again.
6b2071 V.Bend Detection Operation Error
Improper Measurement Mode. (2070)
Make the measurement in the high accuracy mode.
6b3001 V.Bend Detection Error
Coplanarity Error! (3000)
Check for any bent terminals (vertically bent balls and leads).
6b3011 V.Bend Detection Error
Terminal Misregistration Error! (3010)
Check for the position and pitches of the terminals (balls and leads).
6b3021 V.Bend Detection Error
Terminal Detection Error! Wrong Measurement Data (Completely Dark Image).
(3020)
Check the component size and thickness data.
6b3031 V.Bend Detection Error
Terminal Detection Error! Error in Number of Extracted Terminals (labeling).
(3030)
Check the size and pickup position of the component.
6b3041 V.Bend Detection Error
Terminal Detection Error! Terminal Allocation Error (Impossible Terminal
Arrangement Detection). (3040)
Check the component size and thickness data.
6b3061 V.Bend Detection Error
Terminal Detection Error! Edge Detection Error (Impossible Edge Detection of
Gauge during Installation Calibration). (3060)
Check the pickup condition of the calibration gauge and the intallation of the unit.
6b3071 V.Bend Detection Error
Coplanarity Error! (3070)
-----
6b3081 V.Bend Detection Error
Impaired Terminal (Nicked) Error. (3080)
Check the position of the leads or the balls and the quantity data.
6b3091 V.Bend Detection Error
2pinTr Error! (ONE all NG)
Check the component size and thickness data.
6.16 V.Bend Detection System Error
1005-001