173 SOM-2080 Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 809706 PCB Stopper "Disable"was set for the reversal PCB stopper in the sys…

172
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
809201 Library tape width check
The tape width in library and the feeder are not in agreement. Please check the
library and feeder.
809301 Conveyor upper cover opening and closing
Input conveyor upper cover opened.
809302 Conveyor upper cover opening and closing
Input conveyor upper cover closed.
809303 Conveyor upper cover opening and closing
Output conveyor upper cover opened.
809304 Conveyor upper cover opening and closing
Output conveyor upper cover closed.
809305 Conveyor upper cover opening and closing
Input machine conveyor upper cover opened.
809306 Conveyor upper cover opening and closing
Input machine conveyor upper cover closed.
809307 Conveyor upper cover opening and closing
Output machine conveyor upper cover opened.
809308 Conveyor upper cover opening and closing
Output machine conveyor upper cover closed.
809401 PCB existence
The PCB which carried out manual bypass to the input conveyor was detected.
809402 PCB existence
The PCB on a output conveyor was removed.
809501 Conveyor forbidden operation signal detected
The input conveyor changed into the forbidden state of operation.
809502 Conveyor forbidden operation signal detected
The forbidden operation state of the input conveyor of was canceled.
809503 Conveyor forbidden operation signal detected
The output conveyor changed into the forbidden state of operation.
809504 Conveyor forbidden operation signal detected
The forbidden operation state of the output conveyor of was canceled.
809601 Flux automatic reload movement.
The flux automatic reload is running.
809701 PCB Stopper
"Disable"was set for the PCB stopper in the system data.
809702 PCB Stopper
"Disable"was set for the reversal PCB stopper in the system data.
809703 PCB Stopper
"Disable"was set for the PCB stopper in the pattern program data.
809704 PCB Stopper
"Disable"was set for the reversal PCB stopper in the pattern program data.
809705 PCB Stopper
"Disable"was set for the PCB stopper in the system data/ pattern program data.
6.19 Machine Information
1005-001

173
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
809706 PCB Stopper
"Disable"was set for the reversal PCB stopper in the system data/ pattern
program data.
809711 PCB Stopper
The rise operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 90-190ms.
809712 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 90-190ms.
809713 PCB Stopper
The rise operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 90-190ms.
809714 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too slow. Please adjust it
so that an operating time becomes 90-190ms.
809715 PCB Stopper
The drop operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 190-290ms.
809716 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 190-290ms.
809717 PCB Stopper
The drop operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 190-290ms.
809718 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too slow. Please adjust
it so that an operating time becomes 190-290ms.
809801 Feeder alternate condition is disable.
Original and alternated feeders have had pick-up errors and they are under
disabled status. After finding the cause of pick-up errors, go to the main menu,
then [OPERATION], [Altn Mode], select feeder lane number, enable feeder(s)
to clear disabled status, go back to the main menu and press the start button to
resume.
809901 Flux residual quantity detection sensor
It reached the predetermined number of times of a dip, but automatic reload
movement was not carried out. Please confirms quantity of a flux on a disk, and
confirm sensitivity of a sensor.
809902 Flux residual quantity detection sensor
Automatic reload movement was surplus carried out for the predetermined
number of times of a dip. Please confirms quantity of a flux on a disk, and confirm
sensitivity of a sensor.
6.19 Machine Information
1005-001

174
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
809a01 Tray Resupply
Release the lock of the safety cover in the tray resupply section and change the
tray.
After change, lock the cover and press the Resupply button.
809b01 P.C.B. height measure
The measurement had an error but it has been recovered by measuring the
multiple points.
809b02 P.C.B. height measure
Abnormal measured value was found but it has been recovered by measuring the
multiple points.
809C01 Library Bulk Feeder Check
The bulk feeder of library is not in agreement. Please check the library and bulk
feeder.
809d01 Cutter auto return
The cutter auto return mode was performed.
809e01 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(+). Please check the comp position.
809e02 Shuttle Tray Pickup Loc
The P&P X axis position is limit over(-). Please check the comp position.
809e03 Shuttle Tray Pickup Loc
The traverse axis position is limit over(+). Please check the comp position.
809e04 Shuttle Tray Pickup Loc
The traverse axis position is limit over(-). Please check the comp position.
809e05 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(+). Please check the comp position.
809e06 Shuttle Tray Pickup Loc
The shuttle axis position is limit over(-). Please check the comp position.
6.19 Machine Information
1005-001