SOM-2080-001_w.pdf - 第121页
1 18 SOM-2080 6.1 1 Others 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 4b050f Manual Opn Error Error was detected during operation. ----- 4b0601 Auto Run Start Error Production operation has not started …

117
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b0307 Feeder Base
The connector (rear side) for the feeder base worked off. Do not remove the
connector during feeder base ascent.[B0916]
Connect the connector (rear) for the feeder base to the machine main body.
4b0308 Feeder Base
The connector (front side) for the feeder base worked off. Do not remove the
connector during feeder base ascent.[B0916]
Connect the connector (front) for the feeder base to the machine main body.
4b0309 Feeder Base
The check 1 of the feeder base locating in (rear) Y-direction is impossible.[B0910]
Set the feeder base to the machine.
4b030a Feeder Base
The check 2 of the feeder base locating in (rear) Y-direction is impossible.[B0911]
Set the feeder base to the machine.
4b030b Feeder Base
The check 1 of the feeder base locating in (front) Y-direction is impossible.[B0910]
Set the feeder base to the machine.
4b030c Feeder Base
The check 2 of the feeder base locating in (front) Y-direction is impossible.[B0911]
Set the feeder base to the machine.
4b0401 Recycling Conveyor
The recycle conveyer (back) was filled up. [B0924]
Please push a manual switch, and remove parts on the recycling conveyer.
4b0402 Recycling Conveyor
The recycle conveyer (front) was filled up. [B0924]
Please push a manual switch, and remove parts on the recycling conveyer.
4b0403 Recycling Conveyor
The recycling conveyer (back) motor operation time out.
There is a possibility a problem in the motor wiring. Please check the motor
wiring. Please begin the production.
4b0404 Recycling Conveyor
The recycling conveyor (front) motor operation time out.
There is a possibility a problem in the motor wiring. Please check the motor
wiring. Please begin the production.
4b0405 Recycling Conveyor
The component trash box (back) was filled up. [B0925]
Open the safety door, and clean out the wastages in it.
4b0406 Recycling Conveyor
The component trash box (front) was filled up. [B0925]
Open the safety door, and clean out the wastages in it.
4b0501 Manual Opn Error
Operation was not completed within predetermined time.
-----

118
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b050f Manual Opn Error
Error was detected during operation.
-----
4b0601 Auto Run Start Error
Production operation has not started within predetermined time. (Please push a
start button again)
-----
4b0701 Communication Timeout
Communication failed to STG.#1 CPU
-----
4b0702 Communication Timeout
Communication failed to STG.#2 CPU
-----
4b0703 Communication Timeout
Communication failed to Recog CPU
-----
4b0704 Communication Timeout
Communication failed to STG CPU
-----
4b0705 Communication Timeout
The data could not be received in time.
-----
4b0706 Communication Timeout
Since the data could not be received in time, the pitch of the feeder was not
turned back.
Perform the feeder ready OFF and then, ON to return the feeder pitch.
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
-----
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
-----
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
-----
4b0901 Firmware Updating Timeout
Firmware update did not end in prescribed time.
-----
4b0a01 Feeder Alarm
Feeder Alarm. Please confirm the feeder and the component.
-----
4b0b01 Feeder base-main body connector unconnection
The connector on the feeder base-main body was disconnected. [B0916]
Please connect the connector on the feeder base to the main body, and press the
stage leady SW.

119
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b0c01 Nozzle Confirmation Error before Pick-up comp
A component was detected on the nozzle before component pick-up.
Please check placement state on placement step recovery screen.
4b0c02 Nozzle Confirmation Error before Pick-up comp
Residual components were found in the nozzle while production operation.
Please confirm whether there is an error in the P.C.B.
4b0c03 Nozzle Confirmation Error before Pick-up comp
Abandonment is stopped because comp. had been detected on the nozzle.
Please confirm and clean up the nozzle if this error continues.
4b0c04 Nozzle Confirmation Error before Pick-up comp
A component was found on a nozzle after placement and it stayed on the nozzle
after release. Open the safety cover and check the nozzle. Then do Placement
recovery.
Please check placement state on placement step recovery screen.
4b0d01 Serial Out Mode Error
There was no response to the Serial Out Mode.
-----
4b0d02 Serial Out Mode Error
Communication failed to Shtg. of Comp. Host.
-----
4b0d03 Serial Out Mode Error
Communication with the Shtg. of Comp. Host has error.
-----
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b0f01 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of feeder adsorption.
-----
4b0f02 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of nozzle adsorption.
-----
4b1001 Flux spread error
The flux spread was not completed within prescribed time.
Please remove and check flux spread equipment.
4b1101 Conveyance aging
Abnormalities occurred during PCB conveyance axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-L axis, NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
4b1102 Conveyance aging
The timeout occurred in conveyance axis operation during PCB conveyance axis
aging.
Please check motor, amplifier and unusual contents of servo. (NL-L axis, NA-L
axis, NB-L axis, NC-L axis, NR-L axis).