1-26 N67xx DUT Power Supply Installation
Programming the GPIB Address on Power Supplies
Table 1-8 shows the valid GPIB addresses for DUT power supplies. Be sure not to
duplicate a GPIB address if making changes.
Set the GPIB address from the front panel of the DUT power supply.
1 Press ADDR and enter the address.
2 Press ENTER.
Table 1-8 DUT Power Supply Addressing
Power Supply Connection GPIB Address Device File (in /dev/)
Module 0, ASRU Card channels 1-4
Module 0, ASRU Card channels 1, 2, 5, 6
22 ps0
Module 1, ASRU Card channels 1-4
Module 1, ASRU Card channels 1, 2, 5, 6
23 ps1
Module 2, ASRU Card channels 1-4
Module 2, ASRU Card channels 1, 2, 5, 6
24 ps2
Module 3, ASRU Card channels 1-4
Module 3, ASRU Card channels 1, 2, 5, 6
25 ps3
Module 0, ASRU Card channel 5 or 5-6 26 ps4
Module 0, ASRU Card channel 6 27 ps5
Module 1, ASRU Card channels 5-6 28 ps6
Module 1, ASRU Card channel 6 29 ps7
Module 2, ASRU Card channels 5-6 1 ps8
Module 2, ASRU Card channel 6 2 ps9
Module 3, ASRU Card channels 5-6 3 ps10
Module 3, ASRU Card channel 6 4 ps11
Module 0, ASRU Card channel 3 12 ps20
Module 0, ASRU Card channel 4 13 ps21
Module 1, ASRU Card channel 3 15 ps22
Module 1, ASRU Card channel 4 16 ps23
Module 2, ASRU Card channel 3 18 ps24
Module 2, ASRU Card channel 4 19 ps25
Module 3, ASRU Card channel 3 20 ps26
Module 3, ASRU Card channel 4 30 ps27
N67xx DUT Power Supply Installation 1-27
Module 0, Utility Card channel 7 or 7-8 12 ps12
Module 0, Utility Card channel 8 13 ps13
Module 1, Utility Card channel 7 or 7-8 15 ps14
Module 1, Utility Card channel 8 16 ps15
Module 2, Utility Card channel 7 or 7-8 18 ps16
Module 2, Utility Card channel 8 19 ps17
Module 3, Utility Card channel 7 or 7-8 20 ps18
Module 3, Utility Card channel 8 30 ps19
If a supply is split between two modules, use the device file
address and GPIB address of the lower numbered module.
Table 1-8 DUT Power Supply Addressing (continued)
Power Supply Connection GPIB Address Device File (in /dev/)
1-28 N67xx DUT Power Supply Installation
Updating the Configuration Files
The power supply connections must be defined in the system and standard config
files:
\I3070_ICT_ROOT\diagnostics\th1\config
\I3070_ICT_ROOT\standard\config
Use the supplies statement.
supplies <type> <#> asru channel <#>
The supplies type can be ps6751, ps6752, ps6746, or ps6773 depending on
which power supply was installed.
The first number or range of numbers gives the testhead supply number
(
1 through 24). The numbering of the supplies in the supplies statement is
arbitrary. The software will accept any mapping of supply numbers to modules.
However, you cannot assign a power supply number more than once in a
testhead. If the customer has more than one system, make the new
supplies
statement compatible with the other system.
The second number or range of numbers gives the ASRU Card DUT channel.
This must match the physical connection of the supply to the ASRU card. You
cannot assign a channel number (1 through 6) more than once in a module.
The following table shows the default and alternate power supply mapping for each
module and the proper syntax for each type of power supply.
After the
config files have been updated, compile both files.
If the new power supply has been placed on a wrong channel,
you will get a compiler error.