TS560R-USER-GUIDE.pdf - 第11页

22 6. INTERNET of Thing (IoT) 6.1 Setup webserver on the computer 1. Go to Techcon Website (www.techconsystems.com) and download the following files to your computer: a. The “portal.exe” fil e b. The “timezone.z ip” file…

100%1 / 16
10
2. Press the “BAR” icon to change pressure unit to BAR
3. Touch the X icon to save and exit
5.2.3 Spray Time setting
Note: A complete cycle consists of Pre-Spray, Spray and Post-Spray.
Pre-spray: Atomized air turned on before the valve is opened.
Post-spray: Atomized air stayed on after the valve is closed.
1. Touch the “Pre” icon to setup pre-spray time
2. Touch Up and Down arrows to set the desired pre-spray time
23
7. Type: “cd :\iot” then press the “Enter” button
8. Type: “set OKI_IOT_PREFIX=MyPrefix” then press the “Enter” button
22
6. INTERNET of Thing (IoT)
6.1 Setup webserver on the computer
1. Go to Techcon Website (www.techconsystems.com) and download the
following files to your computer:
a. The “portal.exe” file
b. The “timezone.zip” file
2. Create a new folder and name “IoT” or any desired name
3. Copy the “portal.exe” file and the “timezone.zip” file in the “IoT” folder
4. Click on the “Windows” start icon
5. Type: “cmd” in the box (as show below)
6. Press the “Enter” button
The screen should appear as shown below
11
3. Touch the Check Mark icon to save and exit
4. Touch the “Post” icon to setup post-spray time
5. Touch Up and Down arrows to set the desired post-spray time
6. Touch the Check Mark icon to save and exit
5.2.4 Manual/Purge Cycle Setting
1. Touch the Purge icon to select the purge cycle.
The Purge icon will turn to green color.
2. Press and hold down the foot switch to activate the purge cycle.
Alternately, touch and hold the Run icon on the display to activate the
purge cycle.
5.2.5 Automatic Spray Cycle Setting
1. Touch the “Timed” mode icon to set the spray cycle time.
The icon will turn to green color.
2. Touch the “Spray” icon to enter the setup screen
3. Touch the Up and Down arrows to set the desired spray time
Note: The minimum activation is 0.008 second
12
1. Press the Check Mark icon to save and exit
2. Press the foot switch to activate the “Timed” spray cycle.
Alternately, touch the Run icon on the display to activate the “Timed”
spray cycle
Note: The unit has an “Interrupt” mode feature. In this mode, the
“Timed” spray cycle can be disrupted if the foot switch is released and
resumed when the foot wwitch is depressed again.
3. Touch the “Interrupt” icon to activate “Interrupt” mode. The icon will
turn to green color
5.2.6 Teach Mode Setting
In the teach mode, the spray time will be accumulated as long as the foot
switch is depressed. This is helpful in determining the required spray
time when the dispense output is known.
1. Touch the “Teach” icon to enter the teach mode
2. Touch the “Time Reset” icon to set timer to
zero
3. Press and hold down the foot switch, the spray time will be accumulated
4. Release the foot switch when the desired amount of fluid has sprayed
5. Touch the “Timed” icon to transfer the accumulated spray time to “Timed”
mode
6. The unit is now set to repeat this “Timed” cycle
5.2.7 To run in Continous Mode
The controller can be setup to repeat the run continuously.
1. Touch the Setup icon to enter the setup screen
21
5. Touch the Up and Down arrows to select the desired network
6. If the selected network is an unsecured network (not password protected),
touch “Connect” tab to connect.
7. Once the unit is successfully connected to the Wi-Fi network, the
“Connect” tab will change to “Disconnect” and the online symbol will
change to green
8. If the selected network is a secured network (password protected), first
create a text file and type the network’s password, then save the file as
“password.txt”
9. Copy the “password.txt” file to a blank USB thumb drive. Note: Do not put
the “password.txt” file inside a folder
10. Insert the USB drive to the USB port located in the back of the unit
11. Touch “Connect” tab to connect. Once the unit is successufully connected
to the Wi-Fi network, remove the USB drive from the USB port
12. Touch X icon to save and exit
13. Touch the IP Address icon and the unit will show an IP address
Note: Once the unit is turned off, the Wi-Fi connection is lost. To re-connect
the unit back to the same network after the unit is turned on, repeat steps 1-4
and touch the “Default” tab.