INFINITY EX RAIL S YSTEM M ODULE ADJUS TMENTS AN D SETTIN GS 15.1 2 Technical Reference Manual Chapter Issue 2 Jan 04 ADJUSTMEN TS AND SETTINGS Rail Lif ted Sensors Both the left and right rail lifted sensors are through…

INFINITY
EX
RAIL SYSTEM MODULE
SEQUENCES
Chapter Issue 2 Jan 04 Technical Reference Manual 15.11
SEQUENCES
Homing Sequence The rail system is homed during machine initialization only, (during power-up
or upon exiting diagnostics).
When the home command is received the rear moving rail is driven (in the
reverse direction) to the rear of the machine until the home vane, attached to it,
is detected by the rail home sensor. Upon detection (sensor ON) the motor is
driven in the opposite direction until the vane clears the home sensor and the
motor stops (sensor OFF).
This position has a set dimension of 508.5mm to 508.7mm measured between
the inside of each rail, (Positioning section of this chapter refers)
Figure 15-8 Rail Timing Diagram
Rail Positioning There is a fixed relationship between steps of the stepper drive motor and rail
movement (in mm) due to the gearing ratios and pitch of the driving leadscrews.
Therefore when a width is selected this is multiplied by the steps/mm factor and
sent to the stepper drive system.
All positions are relative to the home position.
Home Position
Fwd
Stepper
Motor
Home
Sensor
0V
12V
Stopped
Rev
Vane leaves sensor
Vane enters sensor

INFINITY
EX
RAIL SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
15.12 Technical Reference Manual Chapter Issue 2 Jan 04
ADJUSTMENTS AND SETTINGS
Rail Lifted Sensors Both the left and right rail lifted sensors are through beam optos and mounted
either side of the rising table so to detect premature lifting of the rear rail, as
described in the Drives and Sensors section of this chapter.
The opto vane brackets are height adjustable and are set using a 0.5mm feeler
gauge, so that if either opto is moved by a minimum of 0.5mm above the vane
setting (whilst the table is in the home position), then the LED switches to OFF
indicating an error warning to the operator.
NOTE
Rail Lift Setting figure of this chapter also refers.
Figure 15-9 Rail Lifted Sensor Location
Rail Width Home
Sensor
The rail width home sensor is used to find the home position of the moving rail
and is described in detail in the Sequences section (Homing Sequence) of this
chapter.
The sensor is mounted on an adjustable bracket which enables the position
between the front and rear rails to be set at 508.5mm - 508.7mm, (measured
between the inside edges of both rails, when the moving rail is in the home
position).
A fine adjustment can be made to the set rail dimension by slackening the sensor
forward securing screw and turning the home sensor adjustment screw (Figure
Rail Home Setting refers) in accordance with the table on the next page.
Opto Vane Bracket
Height Adjuster
Rail StopBarOpto Vane Bracket
Height Adjuster
View on Right Hand Side of Machine
NOTE
Rising Table at home position
Rail LiftedRightSensor
(left sensorsimilar)

INFINITY
EX
RAIL SYSTEM MODULE
ADJUSTMENTS AND SETTINGS
Chapter Issue 2 Jan 04 Technical Reference Manual 15.13
NOTE
Rail width home sensor checks are also required if rail parallelism adjustments
are carried out
Figure 15-10 Rail Width board Sensor Location
Home Sensor Screw Adjustment Set Rail Dimension
1 full turn clockwise + 0.5mm
1 full turn anti-clockwise - 0.5mm
Rail Home
Sensor
Rail Home
Opto Flag
(home vane)
508.5 - 508.7 mm
Between inside edges of rails
View on Right Hand Side of Machine