197052.pdf - 第10页

Features QS18 Series Sensor Product Manual 01-Jun-26 page 10 of 29 © Banner Engineering Corp. All rights reserved. www .bannerengineering.com Industry Canada ICES-003(A) This device complies with CAN ICES-3 (A)/NMB-3(…

100%1 / 29
Features QS18 Series Sensor Product Manual
01-Jun-26 page9of29© Banner Engineering Corp. All rights reserved.
www.bannerengineering.com
Specifications
Supply Voltage
10 V DC to 30 V DC (10% maximum ripple) at less than 25
mA, exclusive of load
Protected against reverse polarity and transient voltages
Light Source
Glass Fiber Optic, Opposed and Diffuse mode models:
Infrared, 940 nm
Plastic Fiber Optic, Retroreflective, Convergent models:
Visible red, 660 nm
Fixed-Field and DVS models: Visible red, 630 nm
Adjustments
Glass Fiber Optic, Plastic Fiber Optic, Convergent, Diffuse,
and Retroreflective mode models (only): Single-turn sensitivity
(Gain) adjustment potentiometer
Indicators
Two LED indicators on the sensor top
Green: Power on
Amber: Light sensed
Amber flashing: Marginal excess gain (1 to 1.5 times excess
gain)
Construction
ABS housing
3 mm mounting hardware included
Connections
2 m (6.5 ft) 4-wire PVC cable; 9 m (30 ft) 4-wire PVC cable; 4-
pin M8 or M12 QD; or 150 mm (6 in) cable with a 4-pin M8 or
M12 QD, depending on the model
Repeatability
Opposed Mode: 100 microseconds
DVS, DL and FF Modes: 90 microseconds
All Other Modes: 150 microseconds
Output Configuration
Solid-state complementary (SPDT): NPN or PNP (current
sinking or sourcing), depending on model
Rating: 100 mA maximum each output at 25 °C
DVS, DL and FF Modes ON-state Saturation Voltage: less
than 1.5 V at 10 mA; less than 3 V at 100 mA
All Other Modes: ON-state Saturation Voltage: less than 1 V
at 10 mA; less than 1.5 V at 100 mA
Protected against false pulse on power-up and continuous
overload or short circuit of outputs
Output Response
Opposed Mode: 750 microseconds ON; 375 microseconds
OFF
DVS, FF, and DL Modes: 850 microseconds ON/OFF
All Other Modes: 600 microseconds ON/OFF
100-millisecond delay on power-up; outputs do not conduct
during this time
Environmental
IP67
UL Type 1
Operating Conditions
–20°Cto+70°C(–4°Fto+158°F)
95% at +50 °C maximum relative humidity (non-condensing)
Vibration and Mechanical Shock
All models meet MIL-STD-202F, Method 201A (Vibration: 10
Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude,
10G maximum acceleration) requirements. Also meets IEC
60947-5-2 (Shock: 30G 11 ms duration, half sine wave)
requirements.
Required Overcurrent Protection
WARNING: Electrical connections must
be made by qualified personnel in
accordance with local and national
electrical codes and regulations.
Overcurrent protection is required to be provided by end
product application per the supplied table.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 2.0 30 0.5
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Turck Banner LTD Blenheim House
Blenheim Court
Wickford, Essex SS11 8YT
GREAT BRITAIN
NOTE: For performance specifications of the FF50 and FF100 models built prior to date code 17090, refer
to document p/n 63908.
FCC Part 15 Class A for Unintentional Radiators
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
(Part15.21)Anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatethis
equipment.
FeaturesQS18 Series Sensor Product Manual
01-Jun-26page10of29 © Banner Engineering Corp. All rights reserved.
www.bannerengineering.com
Industry Canada ICES-003(A)
This device complies with CAN ICES-3 (A)/NMB-3(A). Operation is subject to the following two conditions: 1) This device may not cause harmful interference;
and 2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la norme NMB-3(A). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner
d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif.
Dimensions
Model Suffix E, EV, R, and FF
15.0 mm
(0.59")
31.0 mm
(1.22")
3.0 mm
(0.12")
17.1 mm
(0.67")
24.1 mm
(0.95")
35.0 mm
(1.38")
Yellow
LED
Green
LED
Ø3.3 mm (0.13")
Max. torque 0.6 Nm (5 in-lbs)
Model Suffix EB, RB
3.0 mm
(0.12")
21.1 mm
(0.82")
Model Suffix DB, W
3.0 mm
(0.12")
21.1 mm
(0.82")
Model Suffix FP
15.0 mm
(0.59")
7.5 mm
(0.30")
13.4 mm
(0.53")
7.6 mm
(0.30")
17.1 mm
(0.67")
27.5 mm
(1.09")
5.2 mm
(0.21")
31.0 mm
(1.22")
3.0 mm
(0.12")
CV Models:
33.2 mm (1.31")
Model Suffix CV15, CV45, D, DL, LV, LP
Single-turn
Sensitivity
Adjustment
M18x1 Thread
Max. torque 2.3 Nm (20 in-lbs)
Features QS18 Series Sensor Product Manual
01-Jun-26 page11of29© Banner Engineering Corp. All rights reserved.
www.bannerengineering.com
Model Suffix Q7 Model Suffix Q8Model Suffix Q
(e.g. QS186EQ)
Model Suffix Q5
(e.g. QS186EQ5) (e.g. QS186EQ7) (e.g. QS186EQ8)
150 mm (6")
M8 QD
150 mm (6")
M12 QD
41.5 mm
(1.63")
49 mm
(1.93")
Integral
4-pin
M8 QD
Integral
4-pin
M12 QD
M18 x 1 Jam Nut
8.0 mm
(0.32")
24.2 mm
(0.95")
M3 hardware packet contents:
2 - M3 x 0.5 x 20 mm stainless steel
screw
2 - M3 x 0.5 stainless steel hex nut
2 - M3 stainless steel washer
Packing list:
Sensor
M18 x 1 jam nut
M3 hardware packet
Performance Curves
Opposed Mode
Excess Gain Curve Beam Pattern
1
10
100
1 m
3.3 ft
10 m
33 ft
100 m
330 ft
0.1 m
0.3 ft
1000
Excess Gain
Distance
QS186E, EV and
QS18...R
Opposed Mode
20 m
66 ft
16 m
52 ft
12 m
40 ft
8 m
26 ft
4 m
12 ft
0
0
250 mm
500 mm
750 mm
250 mm
500 mm
750 mm
0
10 in
20 in
30 in
10 in
20 in
30 in
Distance
QS186E, EV and QS18...R
Opposed Mode