LA 302 Pressure Controller Manual.pdf - 第31页

Operation 4-1 P/N 71 19797A 2006 Nordson Corporation LA 302 Issued 06/06 Section 4 Operation W ARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this doc…

100%1 / 48
Installation
3-8
P/N 7119797A
2006 Nordson Corporation
LA 302
Issued 06/06
Operation
4-1
P/N 7119797A
2006 Nordson Corporation
LA 302
Issued 06/06
Section 4
Operation
WARNING: Allow only qualified personnel to perform the following tasks.
Observe and follow the safety instructions in this document and all other
related documentation.
WARNING: Risk of splashing. Glue escapes from the adhesive gun when
the solenoid valves are triggered. Wear safety goggles. Do not program
during adhesive gun assembly.
The risk is particularly high during:
Production machine startup
Reverse mode
Manual mode
NOTE: Mode switches and potentiometers on the front of the pressure
controller will be designated alphabetically as mode switch / potentiometer
(A), (B), (C), ... beginning at the top left and moving to the right. The LEDs
are designated LED (1), LED (2), ... beginning at the top left and moving to
the right.
1
LA 302
A
Operation
4-2
P/N 7119797A
2006 Nordson Corporation
LA 302
Issued 06/06
Daily Startup
Switch on mains switch (1).
Fig. 4-1
1 Mains switch
Daily Shutdown
Switch off mains switch.
Switching Off in an Emergency
Switch off mains switch.
Settings
The pressure controller is operated with switches and potentiometers.
Their functions are described in this section.
Selecting Type of Setting (Mode Switch A)
The following parameters are set with mode switch (A):
Measurement of production machine speed
Minimum speed display
Display of minimum and maximum pressure values (in mA) for
proportional valves 1 and 2.
NOTE: All settings are also possible even if the mode switch is not moved.
However, it is advisable to turn the mode switch to the respective position;
otherwise the corresponding value will not appear in the display.
Fig. 4-2