TK26714.PickHeightTeaching.pdf - 第13页
SMT Software Engineering Group IM Operations Y AMAHA MOTOR CO., L TD MDOC-SOFT50389 13/18 On a machine sup ported wit h head va riation, you can select several n ozzle groups. I n t hat case, i t is n ecessa…

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50389
12/18
Item Range Default Description
[Vacuum Check Level]-
Close Vacuum Level
1~30 3 When variation of “Close Vacuum Level” is
over this value, it goes to the next
measurement phase.
[Vacuum Check Level]-
Diff Vacuum Level
1~30 5 Difference between before and after
measurement is larger than this value, an
error occurs.
[Start Pos. Offset(mm)]-
Search Phase
0.0~30.0 5.0
Enter an offset value from the plate height
Z, where “Search Phase” starts.
[End Pos. Offset(mm)]-
Search Phase
0.0~10.0 0.5
Enter an offset value from the plate height
Z, where “Search Phase” finishes.
[End Pos. Offset(mm)]-
Detail Phase
0.0~10.0 1.0 Enter an offset value from the end of
“Search Phase” to where “Detail Phase”
finishes.
[Step Volume(mm)]-
Detail Phase
0.0~1.0 0.03 Enter descent step amount at “Detail
Phase”.
[Step Volume(mm)]-
Up Phase
0.0~1.0 0.01 Enter ascent step amount at “Up Phase”.
Return Offset(mm) 0.0~1.0 0.05 Enter an offset value to move the head up
after “Search Phase” finishes.
Check a nozzle type to be measured.
Checked nozzles are used for height teaching.

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50389
13/18
On a machine supported with head variation, you can select several nozzle groups. In that
case, it is necessary to select nozzles for each group. Select a nozzle group from the combo
box.
< Caution >
When a carbon tape guide is used, 303, 314, 603, 503, and 514 nozzles are not available
for pick height teaching.
4.2 Takeover of Parts Data
Parts data takeover file is saved in “D:¥Machine¥Status¥PartsTakeOver¥” by default. By
setting the saving path to the server, the teaching results can be taken over among several
machines.
To change the takeover file path, open the [Software Setting] – [Monitor] – [Parts Data Take
Over] – [Parts Data Take Over Setting] screen, and enter a file path in [Server Path].
< Caution >
Files in the specified folder can be deleted automatically, so that do not save any other files
than a parts data takeover file "Feeder_*.sts" there.

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50389
14/18
Fig 4.2 [Parts Data Take Over Setting] screen
4.3 Reading fixed board data
This function is supposed to be used with board data that has mount data, but it is available
without mount data as long as fixed board data is read. In this case, mounting heads and
nozzles are automatically determined. Please note that the determined combination of
heads and nozzles will be different from that you want to set.
Read the fixed board data specified in the following screen.
(▲1)