166
3.10.7 Used tape chute
3
Fig. 3.10 - 8 Used tape chute for the changeover table COT insert
3
3
3.10.8 Empty tape duct on the changeover table COT insert
Item no. 03111421-xx Empty tape duct, 12 mm
Item no. 03111420-xx Empty tape duct, 25 mm
PLEASE NOTE
The used tape chute for the E by SIPLACE can only be installed on the changeover table
COT insert for the E by SIPLACE (see fig. 5.16 - 3, page 253)
.
User manual E by SIPLACE 3 Technical data and assemblies
From software version SC 712.1 Edition 05/2019 3.10 Changeover table for E by SIPLACE
167
3
Fig. 3.10 - 9 Empty tape duct on the E by SIPLACE changeover table COT insert
(1) Inlet slot for used tape
(2) Outlet slot for the used tape above the pneumatic tape cutter
(3) Empty tape duct < 12 mm up to 25 mm (can be removed for tapes > 12 mm)
The empty tape duct can guide component tapes with a maximum pocket height of 12 mm. If
feeder modules which use tapes with a pocket height of > 12 mm are used, use the 25 mm
empty tape duct.
3
PLEASE NOTE
Risk of blockages!
When using feeder modules with low pockets next to feeder modules with high pockets,
there is a risk of blockages in the empty tapes.
Do not position feeder modules with shallow pockets immediately beside feeder mod-
ules with deep pockets.
(1)
(2)
(3)
3 Technical data and assemblies User manual E by SIPLACE
3.10 Changeover table for E by SIPLACE From software version SC 712.1 Edition 05/2019
168