Install_EN_00196423-01.pdf - 第13页
Ins ta llat i on and Con fi gur ati on Gu id e SI PLA CE Exp lo rer 1 Int rod uc tio n Edi tio n 05/200 9 E N 1.3 A dd iti onal Remar k s 13 – W hen using MS Windows 2003 Server , the web server (T omcat) must be configu…
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 05/2009 EN
12
– The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual con-
veyors:
The page Production Summary will display Unknown in the Current Recipe List table for
the 2nd conveyor lane. 1
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. There-
fore, only one recipe will be loaded for the SIPLACE line. This recipe will then only be assigned
to conveyor lane I by SIPLACE Explorer. 1
– When using the conveyor type "dual conveyor", the board counting function is subject to limi-
tations. It only records boards for conveyor lane 1. Boards produced on conveyor lane 2 are
not recorded. SIPLACE Explorer and OIS only show the boards for conveyor lane 1. The com-
ponents placed on the boards on conveyor lane 2 are assigned to the boards recorded for lane
1. This means that the number of consumed components shown is correct. This restriction ap-
plies to the following software versions: 407, 408, 502, 503, 504, 505.01, 505.02. The restric-
tion ceases to apply for version 505.03 onwards.
– If partially placed boards are removed from the SIPLACE machine, without specifying this ter-
mination in the station software and removing them via the output conveyor, these boards will
not be recorded by the OIS and SIPLACE Explorer systems. In this case, the station software
is not able to generate the data set needed to record the boards. This restriction applies to all
available versions of the station software. If you need to terminate board placement, always
proceed as follows:
– Terminate the board at the station software interface.
– Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
– The following restrictions apply to the SMA pages listed below, if no boards are placed at the
last station in the production line:
– Machine Navigator:
OLE value will not be shown (N/A).
– Overview of OLE / OEE:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be
shown correctly.
Overall Equipment Efficiency by Station diagram: station data is not shown correctly for
stations which do not place boards.
– OEE Analysis:
Table: values for performance and availability will not be shown correctly for lines and sta-
tions which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OLE, perfor-
mance and availability will not be shown correctly for the line.
Installation and Configuration Guide SIPLACE Explorer 1 Introduction
Edition 05/2009 EN 1.3 Additional Remarks
13
– When using MS Windows 2003 Server, the web server (Tomcat) must be configured accord-
ingly. For further details about the configuration process, refer to “Using Windows 2003 Server”
on page 46.
– The name of the computer on which Tomcat is installed may not include special characters, in
particular no underscore (_). If the name does include these characters, it will not be possible
to display the website. For further details about this restriction, see "http://support.mi-
crosoft.com/kb/275033".
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 05/2009 EN
14